Technical guideCitationYear not stated

Direct Liquid Cooling: CAPEX and OPEX, the Complete ROI Story

STULZ / CoolIT

A STULZ and CoolIT white paper comparing air conditioning, direct liquid cooling (DLC) and hybrid options through capital (CAPEX) and operating (OPEX) cost.

On this page

Overview

The white paper says data centres face major cooling costs from rising workloads and hardware thermal requirements, have traditionally used air conditioning, and are seeing cooling technologies from the high performance computing (HPC) sector move into the enterprise. Direct liquid cooled (DLC) systems are increasingly used in modern data centres.

According to the text, both air conditioning and DLC are needed to meet cooling demand. Organisations are advised to consider CAPEX and OPEX together to decide when to use air conditioning, a DLC solution or a hybrid. The paper gives an overview of STULZ air conditioning solutions and CoolIT DLC solutions.

Key points

  1. Publishers: STULZ and CoolIT; subject is a CAPEX and OPEX comparison of air conditioning, DLC and hybrid options.
  2. Cooling technologies from the HPC sector are moving into enterprise data centres.
  3. Both air conditioning and DLC are needed to meet cooling demand.
  4. Which solution fits when is decided by weighing CAPEX and OPEX together.
  5. Scope: overview of STULZ air conditioning and CoolIT DLC solutions.

Using it in design

  • Compare CAPEX and OPEX for air, DLC and hybrid scenarios on the same rack density and lifetime using your own data.
  • Plan capacity and redundancy separately for the air-cooled and liquid-cooled parts of the hall.
  • In a hybrid design, size the residual air heat load that DLC does not capture separately.

Who should read it

Data centre owners and designers making investment decisions between air and liquid cooling.

Publication details

Authors
STULZ / CoolIT
Publisher
STULZ / CoolIT
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Publisher landing page opened with web and TinyFish; HTML contains a HubSpot download form. No open reuse licence is stated. Metadata and landing-page summary only; year not confirmed.

Citation

STULZ / CoolIT Direct Liquid Cooling: CAPEX and OPEX, the Complete ROI Story. STULZ / CoolIT. https://info.stulz-usa.com/direct-liquid-cooling-white-paper

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.