State-of-the-Art Power Electronics in AI Data Centers

IEEE Open Journal of Power Electronics (Institute of Electrical and Electronics Engineers (IEEE)), 2026, Research paper

This IEEE Open Journal of Power Electronics review benchmarks the AI power chain from grid to processor across four conversion stages: PSU, high-voltage IBC, on-board low-voltage IBC and VRM, and…

Research paper

2026

PDF

Stochastic Models for Optimizing Availability, Cost and Sustainability of Data Center Power Architectures through Genetic Algorithm

Revista de Informática Teórica e Aplicada (Universidade Federal do Rio Grande do Sul), 2019, Research paper

Austregésilo and Callou's 2019 paper couples reliability block diagrams, stochastic Petri nets and an energy flow model with a multi-objective genetic algorithm to optimise equipment selection in a…

Research paper

2019

Read at publisher (opens in a new tab)

Sustainable Supercomputing for AI: GPU Power Capping at HPC Scale

Proceedings of the 2023 ACM Symposium on Cloud Computing (ACM), 2023, Research paper

A vision paper analysing the effect of a system-wide GPU power cap (60% of peak) at the MIT supercomputing center, which runs nodes with two V100 GPUs each, using more than 123,000 GPU jobs, about…

Research paper

2023

PDF

Techno-economic analysis of a PV/T waste heat–driven compound ejector-heat pump for simultaneous data centre cooling and district heating using low global warming potential refrigerants

Mitigation and Adaptation Strategies for Global Change (Springer Science and Business Media LLC), 2022, Research paper

Universitat Jaume I researchers simulate a compound ejector heat pump that cools a data centre and at the same time delivers recovered heat to a district heating network, with waste heat from a PV/T…

Research paper

2022

PDF

The Unseen AI Disruptions for Power Grids: LLM-Induced Transients

arXiv preprint (University of Alberta), 2024, Research paper

An early and widely cited paper arguing that the dynamic power behaviour of LLM workloads, rather than energy alone, is a grid reliability issue, describing AI loads as having very low inertia, sharp…

Research paper

2024

PDF