RegulationPDF2014

Elektrik Tesisleri Proje Yönetmeliği (Regulation on Electrical Installation Projects)

Original title Elektrik Tesisleri Proje Yönetmeliği

T.C. Enerji ve Tabii Kaynaklar Bakanlığı

A Turkish regulation on the preparation and approval of electrical installation projects and the authorisation of bodies that approve projects and accept completed installations.

Copyright retained; citation only: the publisher’s terms apply to the original document

On this page

Overview

The Elektrik Tesisleri Proje Yönetmeliği (Regulation on Electrical Installation Projects) was issued by the Ministry of Energy and Natural Resources and published in the supplementary issue of Resmî Gazete No. 29221 on 30 December 2014. Its purpose is to ensure that project approvals comply with legislation, standards and specifications, that connection to the grid is compatible, and that the safety of life, property and environment is maintained. The purpose article was amended on 10 May 2021 (Article 1(1)).

The scope (Article 2(1)) is the preparation and approval of projects for new or modified electrical installations, and the authorisation of the bodies that approve projects and accept completed installations. For a designer, what matters in this frame is which hierarchy of standards a project must follow and whose signature it must carry when submitted for approval. The rule thus links the technical content of a project to a named, accountable professional.

Article 5(1)(a)-(b) sets out the hierarchy of standards to follow in design: Turkish Standards (TS) or standards accepted by TSE, EN standards published by CEN/CENELEC/ETSI, IEC/ISO standards, and internationally accepted codes such as IEEE, ASME and ASTM. Article 6(1)-(2) requires projects to be prepared and signed by engineers of the relevant discipline holding the required certificates. An electrical project therefore does not enter the approval process without the responsible engineer's signature.

This record is based on the consolidated text read from mevzuat.gov.tr, current as of November 2026. This summary does not cover all articles; for details such as acceptance procedures, authorisation conditions and penalty provisions, the regulation itself and the related Elektrik Tesisleri Kabul Yönetmeliği and Elektrik İç Tesisleri Yönetmeliği should be consulted.

Key points

  1. Resmî Gazete 29221 supplementary issue, 30.12.2014.
  2. Purpose: project approvals in line with legislation, standards and specifications, grid-compatible connection, and safety of life, property and environment (Article 1(1), amended 10/5/2021).
  3. Covers project preparation and approval for new or modified electrical installations (Article 2(1)).
  4. Also covers authorisation of bodies that approve projects and accept completed installations.
  5. Design must follow TS or TSE-accepted standards, CEN/CENELEC/ETSI EN, IEC/ISO, and internationally accepted codes such as IEEE, ASME, ASTM (Article 5(1)(a)-(b)).
  6. Projects are prepared and signed by engineers of the relevant discipline holding the required certificates (Article 6(1)-(2)).
  7. Related documents: Elektrik Tesisleri Kabul Yönetmeliği, Elektrik İç Tesisleri Yönetmeliği, IEC 60364 series.

Using it in design

  • In export and QA, tag every rule and calculation with the standard used so the TR project-approval package can show the TS/EN/IEC/IEEE hierarchy.
  • Include a signatory block for the responsible discipline engineer on exported drawings.
  • For projects in Turkey, justify standard selection starting from TS or TSE-accepted standards.
  • Assess the project-approval package together with the Acceptance Regulation and the Internal Installations Regulation.

Who should read it

Engineers and design offices preparing and submitting electrical projects in Turkey, and specialists managing acceptance procedures.

Related standards

  • Elektrik Tesisleri Kabul Yönetmeliği
  • Elektrik İç Tesisleri Yönetmeliği
  • IEC 60364 series

Read the document

tr-elektrik-tesisleri-proje-yonetmeligi.pdf

PDF · 0.3 MB · Turkish

Copyright retained; citation only: the publisher’s terms apply to the original document

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
T.C. Enerji ve Tabii Kaynaklar Bakanlığı
Publisher
T.C. Enerji ve Tabii Kaynaklar Bakanlığı
Year
2014
Document number
RG 29221 mükerrer (30.12.2014)
Document language
Turkish
Source type
Turkish regulation
Access
Open licence (downloadable)
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Licence evidence
www.mevzuat.gov.tr
Original licence note

Official Turkish legislation published in the Resmî Gazete; FSEK (Law 5846) Art. 31 allows laws and regulations to be reproduced freely.

Citation

T.C. Enerji ve Tabii Kaynaklar Bakanlığı (2014). Elektrik Tesisleri Proje Yönetmeliği. T.C. Enerji ve Tabii Kaynaklar Bakanlığı. RG 29221 mükerrer (30.12.2014). https://www.mevzuat.gov.tr/MevzuatMetin/yonetmelik/7.5.20383.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.