Trane Centrifugal Chillers EPD 4790566295.101.1
Trane Technologies / UL Environment · Trane Technologies
2023 environmental product declaration issued with UL Environment for Trane Technologies' centrifugal water-cooled chillers, giving a product-stage carbon figure.
On this page
Overview
This document is the 2023 environmental product declaration (EPD 4790566295.101.1) for Trane Technologies' water-cooled centrifugal chillers, issued with UL Environment.
The one numerical finding in the record is this: the production-weighted average of six Trane water-cooled centrifugal chillers reports an A1-A3 IPCC GWP of 129 kg CO2e per refrigeration ton of cooling capacity (page 14, Table 18; declared unit on page 2). This product-stage result is separate from operational energy and replacement stages, so it shows only the embodied part from raw materials, transport and manufacturing, not a chiller's total life-cycle carbon.
The limit on use is important: product-specific data must be explicitly labelled as proxies when applied to generic equipment. Because the document provides one data point for a specific product family, it should not be treated as directly valid for other manufacturers, capacities or chiller types. For a real project, the selected product's own EPD or manufacturer data should be used.
Key points
- The document is EPD 4790566295.101.1, issued by Trane Technologies with UL Environment in 2023.
- Its subject is centrifugal water-cooled chillers.
- Production-weighted average of six Trane water-cooled centrifugal chillers: A1-A3 IPCC GWP of 129 kg CO2e per refrigeration ton of cooling capacity.
- The value is a product-stage result, separate from operational energy and replacement stages.
- The source value is on page 14, Table 18; the declared unit is on page 2.
- Product-specific data must be labelled as proxies when applied to generic equipment.
Using it in design
- In preliminary embodied-carbon calculations, use 129 kg CO2e per refrigeration ton as a proxy factor for water-cooled centrifugal chillers and label it as a proxy.
- Use the figure only for the A1-A3 product stage; calculate operational energy separately.
- As the project matures, replace it with the selected chiller's own EPD and update the data-quality label.
Who should read it
Sustainability consultants and designers calculating embodied carbon for cooling equipment.
Publication details
- Authors
- Trane Technologies
- Publisher
- Trane Technologies / UL Environment
- Year
- 2023
- Document language
- English
- Source type
- Manufacturer
- Access
- Citation only
- Licence
- Bibliographic reference only: the document is not redistributed here; confirm reuse terms at the original source
Citation
Trane Technologies (2023). Trane Centrifugal Chillers EPD 4790566295.101.1. Trane Technologies / UL Environment. https://aem-dev.mtechapis.com/content/dam/Trane/Commercial/global/products-systems/equipment/chillers/water-cooled/101.1_EPD_TraneTechnologiesChiller.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.