VXK Rear Door Heat Exchanger

VNCOOL

The VNCOOL VXK series offers rear-door cooling of 3-76 kW per cabinet in heat-pipe, chilled-water and fan-assisted routes; the heat-pipe route keeps water out of the white space.

On this page

Overview

VNCOOL (Shenzhen) presents the VXK rear door heat exchanger as close-coupled cooling at the heat source for high-density racks, AI computing clusters and modular data centres. The series is available in heat-pipe, chilled-water and fan-assisted configurations and delivers sensible cooling with rapid thermal response and minimal impact on room conditions.

Points the page stresses: the heat-pipe route suits finance, healthcare and high-performance computing (HPC) sites that prohibit water in the white space; three technology routes are offered on one platform so the route can match the site; the same product covers retrofit cabinets and the densest AI racks; door geometry fits existing cabinets without bespoke sheet-metal work; and it connects to an existing BMS without bespoke integration engineering.

Technical data: capacity 3-76 kW per cabinet; refrigerants R410A, R134a, R22 and water (route-dependent); single-leaf or dual-leaf door; cabinet depth +100 to +210 mm; PID control with local LCD touchscreen and BMS-ready integration. The heat-pipe route has no water or condensate in the white space. Applications are AI/HPC cabinets, finance and telecom core, healthcare imaging and retrofit rooms. The page gives no discrete ordering models or full rating points.

Key points

  1. Three technology routes: heat-pipe, chilled-water and fan-assisted rear door.
  2. Capacity is 3-76 kW per cabinet.
  3. Refrigerant or medium: R410A, R134a, R22 and water (route-dependent).
  4. Single- or dual-leaf door; cabinet depth increases by +100 to +210 mm.
  5. PID control with local LCD touchscreen; BMS-ready.
  6. The heat-pipe route has no water or condensate in the white space.
  7. Applications: AI/HPC cabinets, finance and telecom core, healthcare imaging, retrofit rooms.
  8. The page has no model-level ordering table or full rating points.

Using it in design

  • At sites where water is prohibited in the white space, evaluate the heat-pipe route as the option with no water supply or condensation risk.
  • For retrofit cabinets check the +100 to +210 mm extra rear-door depth against aisle width and door swing.
  • To select within the 3-76 kW per cabinet range, ask the manufacturer for model-level ratings (water temperature, air inlet condition).
  • Write PID and BMS integration (protocol, alarm points) into the commissioning plan.

Who should read it

Data-centre designers choosing rear-door cooling for high-density AI/HPC racks and retrofit rooms.

Document contents

  1. Why VXK Rear Door Heat Exchanger
  2. Most important technical data
  3. Technology routes
  4. Applications
  5. About VNCOOL

Publication details

Authors
VNCOOL
Publisher
VNCOOL
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

VNCOOL VXK Rear Door Heat Exchanger. VNCOOL. https://www.ivisioncool.net/vxk-rear-door-heat-exchanger-product/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.