VXK Rear Door Heat Exchanger
VNCOOL
The VNCOOL VXK series offers rear-door cooling of 3-76 kW per cabinet in heat-pipe, chilled-water and fan-assisted routes; the heat-pipe route keeps water out of the white space.
On this page
Overview
VNCOOL (Shenzhen) presents the VXK rear door heat exchanger as close-coupled cooling at the heat source for high-density racks, AI computing clusters and modular data centres. The series is available in heat-pipe, chilled-water and fan-assisted configurations and delivers sensible cooling with rapid thermal response and minimal impact on room conditions.
Points the page stresses: the heat-pipe route suits finance, healthcare and high-performance computing (HPC) sites that prohibit water in the white space; three technology routes are offered on one platform so the route can match the site; the same product covers retrofit cabinets and the densest AI racks; door geometry fits existing cabinets without bespoke sheet-metal work; and it connects to an existing BMS without bespoke integration engineering.
Technical data: capacity 3-76 kW per cabinet; refrigerants R410A, R134a, R22 and water (route-dependent); single-leaf or dual-leaf door; cabinet depth +100 to +210 mm; PID control with local LCD touchscreen and BMS-ready integration. The heat-pipe route has no water or condensate in the white space. Applications are AI/HPC cabinets, finance and telecom core, healthcare imaging and retrofit rooms. The page gives no discrete ordering models or full rating points.
Key points
- Three technology routes: heat-pipe, chilled-water and fan-assisted rear door.
- Capacity is 3-76 kW per cabinet.
- Refrigerant or medium: R410A, R134a, R22 and water (route-dependent).
- Single- or dual-leaf door; cabinet depth increases by +100 to +210 mm.
- PID control with local LCD touchscreen; BMS-ready.
- The heat-pipe route has no water or condensate in the white space.
- Applications: AI/HPC cabinets, finance and telecom core, healthcare imaging, retrofit rooms.
- The page has no model-level ordering table or full rating points.
Using it in design
- At sites where water is prohibited in the white space, evaluate the heat-pipe route as the option with no water supply or condensation risk.
- For retrofit cabinets check the +100 to +210 mm extra rear-door depth against aisle width and door swing.
- To select within the 3-76 kW per cabinet range, ask the manufacturer for model-level ratings (water temperature, air inlet condition).
- Write PID and BMS integration (protocol, alarm points) into the commissioning plan.
Who should read it
Data-centre designers choosing rear-door cooling for high-density AI/HPC racks and retrofit rooms.
Document contents
- Why VXK Rear Door Heat Exchanger
- Most important technical data
- Technology routes
- Applications
- About VNCOOL
Publication details
- Authors
- VNCOOL
- Publisher
- VNCOOL
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
VNCOOL VXK Rear Door Heat Exchanger. VNCOOL. https://www.ivisioncool.net/vxk-rear-door-heat-exchanger-product/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.