Top Energy-Saving Tips for Setting up your Co-Location Data Center (ENERGY STAR flyer, 2023)
U.S. Environmental Protection Agency (ENERGY STAR) · U.S. Environmental Protection Agency
A one-page ENERGY STAR flyer for tenants fitting out space in a colocation facility. It covers certified IT hardware, set points, airflow management, cabling and hot-aisle/cold-aisle layout.
U.S. public domain — U.S. Government work; free to reuse
On this page
Overview
The flyer gives tenants five practical recommendations. First, buy ENERGY STAR IT hardware: a certified server with power management enabled uses on average almost 40% less energy than a non-certified one, and avoiding an unneeded server could save over $8,500. Certification also exists for data storage and for UPSs.
Second, maximise temperature and humidity set points. Going below the optimum level costs the HVAC more energy, while exceeding it puts more burden on IT equipment and likely shortens its life. The flyer states that ASHRAE and IT manufacturers have updated their recommendation so that equipment can safely run up to 80-81 F and 50% humidity without longevity or uptime concerns.
Third, airflow: blanking panels, floor tiles, gap fillers and server ducting reduce cooling needs, and proper airflow management can save up to 15% of energy use in IT alone. Network cables and rack layout must not obstruct airflow, illustrated with good and bad cabling photographs. Last, hot-aisle/cold-aisle layouts are described as one of the most proven ways to save energy in a data centre.
Key points
- An ENERGY STAR certified server with power management enabled uses on average almost 40% less energy than a non-certified product.
- Avoiding an unneeded server can save over $8,500.
- ASHRAE and IT manufacturers allow operation up to 80-81 F and 50% humidity without longevity or uptime concerns.
- Proper airflow management can save up to 15% of energy use in IT alone.
- Blanking panels, floor tiles, gap fillers and server ducting reduce the cooling needed.
- Cabling and rack layout must not impede airflow; poor cabling can shorten hardware life.
- Hot-aisle/cold-aisle layout is presented as one of the most proven energy-saving methods.
Using it in design
- Make a blanking-panel and gap-filler check a required step in colocation cage and rack layouts, and flag unused rack units.
- Orient racks to the hot-aisle/cold-aisle alignment and verify equipment airflow direction.
- Test set-point suggestions within ASHRAE and manufacturer limits, using the flyer's 80-81 F and 50% humidity reference.
- Plan cable routes so they do not block airflow.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Compare the cost of design decisions
Evaluate equipment costs, energy expenses and total cost of ownership (TCO) using your inputs and assumptions in SoSo CAD.
Request a demo
Who should read it
IT teams renting colocation space and facility managers who guide those tenants on layout.
Document contents
- Buy ENERGY STAR IT Hardware
- Maximize Temperature and Humidity Set Points
- Mind the Gaps!
- Keep Things Free and Clear
- Separate Hot and Cold
Related standards
- ASHRAE Thermal Guidelines for Data Processing Environments
Read the document
energystar-colocation-best-practices.pdf
U.S. public domain — U.S. Government work; free to reuse
The document is provided unaltered because its licence permits redistribution.
Publication details
- Authors
- U.S. Environmental Protection Agency
- Publisher
- U.S. Environmental Protection Agency (ENERGY STAR)
- Year
- 2023
- Document language
- English
- Source type
- Government / public
- Access
- Open licence — downloadable
- Licence
- U.S. public domain — U.S. Government work; free to reuse
- Licence evidence
- www.copyright.gov
Original licence note
Work of the U.S. Environmental Protection Agency ENERGY STAR program (federal agency publication on energystar.gov); not subject to copyright under 17 U.S.C. 105.
Citation
U.S. Environmental Protection Agency (2023). Top Energy-Saving Tips for Setting up your Co-Location Data Center (ENERGY STAR flyer, 2023). U.S. Environmental Protection Agency (ENERGY STAR). https://www.energystar.gov/sites/default/files/asset/document/ES-data-center-flyer-draft-032723-v2.pdf
Events on this subject
- SC26 – International Conference for High Performance Computing, Networking, Storage and Analysis
- ASHRAE Winter Conference
- AHR Expo
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.