EPRI DCFlex - Data Center Flexibility Initiative (programme site)
EPRI (Electric Power Research Institute) · EPRI
The programme site for EPRI's DCFlex collaborative, which studies how data centres can flex load to support grid reliability and faster interconnection.
On this page
Overview
DCFlex is a collaborative programme of EPRI (Electric Power Research Institute) that studies how data centres can flex their load to support grid reliability and faster grid interconnection. The source is a programme site, not a report or standard, so its content is more a presentation of ongoing work.
The programme tests real-time data centre flexibility at nine active demonstration sites. Work runs through five workstreams: Workstream 1 covers grid-informed flexible data centre designs and operating practices, Workstream 3 flexible interconnection practices and study frameworks, and Workstream 5 distribution-connected data centres (DxDCs).
The site also links to a DCFlex Oscillations page on the grid impacts of dynamic data centre loads. This shows that the power-swing and oscillation risks of rapidly varying loads, such as AI training clusters, are being followed within the programme.
The limit is that results are not summarised in the record; only the programme structure and the number of demonstrations are known. IEEE 2800 (analogous) and NERC large-load guidance are named as related. Its value for designers is as a pointer to which parameters to expect in flexible-interconnection studies.
Key points
- DCFlex tests real-time data centre flexibility at nine active demonstration sites.
- Workstream 1: grid-informed flexible data centre designs and operating practices.
- Workstream 3: flexible interconnection practices and study frameworks.
- Workstream 5: distribution-connected data centres (DxDCs).
- The site hosts a DCFlex Oscillations page on grid impacts of dynamic data centre loads.
- The programme comprises five workstreams.
Using it in design
- In the electrical/grid module, let users declare a flexible-load capability (curtailable MW, duration, ride-through via BESS) for interconnection studies.
- Flag AI training clusters for power-swing and oscillation review.
- Use the DxDC workstream as a reference for distribution-connected facilities.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Electrical engineers and data centre developers planning grid interconnection and flexible-load strategy.
Related standards
- IEEE 2800 (analogous)
- NERC large load guidance
Publication details
- Authors
- EPRI
- Publisher
- EPRI (Electric Power Research Institute)
- Year
- 2026
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Public EPRI programme web page; no open licence; cited only.
Citation
EPRI (2026). EPRI DCFlex - Data Center Flexibility Initiative (programme site). EPRI (Electric Power Research Institute). https://msites.epri.com/dcflex