Information technology - Data centre facilities and infrastructures - Part 6: Security systems
ISO/IEC · ISO/IEC JTC 1
The standard on physical security of data centres following the Part 1 classification, with requirements against unauthorized access, intrusion, internal fire and environmental events.
On this page
Overview
ISO/IEC 22237-6 covers the physical security of data centres and follows the classification in Part 1 of the ISO/IEC 22237 series. It assigns designations to the data centre spaces defined in Part 1 and sets requirements according to the protection level of each space. The first edition, published in 2024, runs to 34 pages and replaces the 2018 technical specification ISO/IEC TS 22237-6.
The requirements fall into several threat groups: protection against unauthorized access through both organizational and technological solutions; protection against intrusion; protection against fires igniting within data centre spaces; and protection against internal non-fire environmental events and external events that affect the defined protection level. Constructional requirements are given by reference to ISO/IEC 22237-2. This grouping means security design has to consider both physical and organizational measures together.
The document is a paid standard, and only the publisher's public catalogue abstract and product data were used here; the full text was not read. Details of class levels, quantitative values and test methods must therefore be taken from the original. The standard treats security as part of a classification of spaces and protection levels rather than as a matter of individual products.
Key points
- Provides designations for the data centre spaces defined in ISO/IEC 22237-1.
- Requires protection against unauthorized access through organizational and technological solutions, and against intrusion.
- Requires protection against internal fire events igniting within data centre spaces.
- Requires protection against internal non-fire and external environmental events, according to the defined protection level.
- Constructional requirements are given by reference to ISO/IEC 22237-2.
- Edition 1 was published 2024-02-19, runs to 34 pages and replaces ISO/IEC TS 22237-6:2018.
Using it in design
- Tag each room in the floor plan with a protection class and check that access-control zones nest correctly, so a higher-class room is not reachable except through lower-class rooms.
- Feed the room classes into the defaults for fire detection and suppression.
- Document separate protection decisions for intrusion, internal fire and environmental events in the design report.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Bring standards pre-checks into your project
Review model-based TS EN 50600 and Tier pre-checks, missing inputs and items requiring engineering review in SoSo CAD.
Request a demo
Who should read it
Engineers and security consultants designing physical security, fire protection and building layout for data centres.
Related standards
- EN 50600-2-5
- ISO/IEC 22237-2
- NFPA 75
Publication details
- Authors
- ISO/IEC JTC 1
- Publisher
- ISO/IEC
- Year
- 2024
- Document number
- ISO/IEC 22237-6:2024
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
ISO/IEC JTC 1 (2024). Information technology - Data centre facilities and infrastructures - Part 6: Security systems. ISO/IEC. ISO/IEC 22237-6:2024. https://webstore.iec.ch/en/publication/92578
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.