Air-Assisted Direct Liquid Cooling: An Overlooked Option

Uptime Institute Intelligence · J. Williams-George, D. Bizo

A short Uptime Intelligence report on direct liquid cooling (DLC) designs that reject heat to room air instead of facility water.

On this page

Overview

This document is a five-page report from Uptime Institute Intelligence, published as UII Update 233 in the first quarter of 2024 and written by J. Williams-George and D. Bizo. Its subject is direct liquid cooling (DLC) designs that pass heat to room air rather than to a facility water connection. The report sits behind a registration form or subscription; only the information on the public landing page has been used here.

The starting point is that the need for a facility water connection is a key barrier to DLC in air-cooled facilities. Air-assisted DLC removes that requirement because it rejects heat to air instead of water. Liquid-cooled servers can therefore be placed more easily in existing halls that have no water infrastructure. There is a price: according to the landing page, the approach trades some performance for ease of deployment and operation.

The public page gives no numbers on how large that performance penalty is. The document is therefore a short assessment pointing to an overlooked option, not a full design guide. The practical takeaway for engineers is that moving an air-cooled site to liquid cooling does not always require a new water loop, but the rejected heat still ends up in the room air and therefore loads the air-conditioning system.

Key points

  1. Air-assisted DLC removes heat to air instead of a facility water connection.
  2. The facility water connection requirement is a key barrier to DLC in air-cooled facilities.
  3. Published as UII Update 233 in Q1 2024.
  4. Five-page report by J. Williams-George and D. Bizo.
  5. The approach trades some performance for ease of deployment and operation.
  6. The full report is behind registration or subscription.

Using it in design

  • Offer a 'liquid-to-air CDU / sidecar' as a DLC option.
  • Add the heat rejected to room air to the CRAH sizing.
  • For existing halls without water infrastructure, compare facility-water DLC with air-assisted DLC on cost and performance.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Check cooling capacity alongside your design

Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.

Request a demo
Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Who should read it

Designers and operations engineers considering adding liquid cooling to existing air-cooled halls.

Publication details

Authors
J. Williams-George; D. Bizo
Publisher
Uptime Institute Intelligence
Year
2024
Document number
UII Update 233
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Report behind a registration form (or Uptime Intelligence subscription); copyright Uptime Institute. Facts taken only from the public landing page / press release. Citation only.

Citation

J. Williams-George; D. Bizo (2024). Air-Assisted Direct Liquid Cooling: An Overlooked Option. Uptime Institute Intelligence. UII Update 233. https://uptimeinstitute.com/resources/research-and-reports/air-assisted-direct-liquid-cooling-an-overlooked-option

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.