Technical guideCitation2022

Silicon Heatwave: The Looming Change in Data Center Climates

Uptime Institute Intelligence · D. Bizo

An Uptime Intelligence report by D. Bizo on how rising server and processor power since the mid-2010s affects air cooling and facility temperatures.

On this page

Overview

This document is a report by D. Bizo, published by Uptime Institute Intelligence in August 2022 as UII Briefing Report 74. Its subject is the steep rise in typical server power consumption since the mid-2010s and what it means for data center climate control. The full text requires registration or a subscription; the information on this page is drawn only from the key findings on the public landing page.

According to the key findings, the rise is driven chiefly by server processor (silicon) power, and the trend is expected to continue. The high thermal power and lower temperature limits of next-generation processors challenge air cooling and efficiency. In other words, processors produce more heat while the temperature range in which they can operate narrows, and together these effects create a need for colder supply air or different cooling methods on the facility side.

The report stresses that operators face complex decisions on whether and how to prepare facilities for higher-power servers. That decision affects the limits of existing facilities, the design envelope of new ones and the timing of any move to liquid cooling. The public summary does not give a numerical comparison of these options; such detail sits in the full text of the report.

The findings summarized here are qualitative trends; no specific temperature threshold or power value appears in the public summary. Even so, the report is a frequently used context source for questioning supply-temperature assumptions in air-cooled designs and for justifying the need for liquid cooling.

Key points

  1. UII Briefing Report 74, August 2022, by D. Bizo.
  2. Typical server power consumption has risen steeply since the mid-2010s and is expected to keep rising.
  3. The main driver is server processor (silicon) power.
  4. High thermal power and lower temperature limits of next-generation processors challenge air cooling and efficiency.
  5. Operators face complex decisions on whether and how to prepare facilities for higher-power servers.
  6. The report is behind registration or a subscription; this summary uses only the public key findings.

Using it in design

  • Plan for lower supply temperatures, H1-class rooms or liquid cooling when high-TDP servers are selected.
  • Re-validate the supply-air temperature assumption of an air-cooled design against the temperature limits of the target server generations.
  • State in the design notes how the facility will accommodate future growth in server power (space, pathways, power).
  • Assess separately how a lower supply temperature affects free-cooling hours in the cooling efficiency calculation.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Check cooling capacity alongside your design

Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.

Request a demo
Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Who should read it

Cooling and mechanical designers, capacity planners and engineers selecting server platforms.

Publication details

Authors
D. Bizo
Publisher
Uptime Institute Intelligence
Year
2022
Document number
UII Briefing Report 74
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Report behind a registration form (or Uptime Intelligence subscription); copyright Uptime Institute. Facts taken only from the public landing page / press release. Citation only.

Citation

D. Bizo (2022). Silicon Heatwave: The Looming Change in Data Center Climates. Uptime Institute Intelligence. UII Briefing Report 74. https://uptimeinstitute.com/resources/research-and-reports/silicon-heatwave-the-looming-change-in-data-center-climates

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.