The Sustainable Data Centre Action Plan

State of Victoria, Department of Jobs, Skills, Industry and Regions

Victoria's 2026 action plan coordinates land, grid, water and local-benefit expectations for data centres: operational electricity should be offset by new renewable supply and storage, and water-intensive cooling should use non-drinking water.

On this page

Overview

The plan, from the State of Victoria's Department of Jobs, Skills, Industry and Regions (ISBN 978-1-76090-716-7), brings together land, grid, water and local-benefit expectations for data centres. Some compliance and verification settings remain to be developed; the plan is not evidence that every proposed measure is already implemented.

On energy, new renewable supply and storage are expected to offset operational electricity, with detailed verification and firming settings still to be finalised. On water, water-intensive cooling should use non-drinking supplies or an agreed transition, with arrangements for interim drinking-water use.

Key points

  1. The plan coordinates land, grid, water and local-benefit expectations.
  2. New renewable supply and storage are expected to offset operational electricity.
  3. Detailed verification and firming settings are still to be finalised.
  4. Water-intensive cooling should use non-drinking supplies or an agreed transition.
  5. Arrangements cover interim drinking-water use during the transition.

Using it in design

  • In the cooling concept make non-drinking water access or a utility transition agreement a precondition for water-intensive systems.
  • Write the renewable supply and storage source and the verification method into the design file as the energy strategy.
  • Plan an interim drinking-water scenario for the transition period and a backup cooling solution for water restrictions.
  • Track the compliance settings still to be finalised and leave schedule flexibility.

Who should read it

Designers, planning consultants and investors developing data centres in Victoria.

Publication details

Authors
State of Victoria, Department of Jobs, Skills, Industry and Regions
Publisher
State of Victoria, Department of Jobs, Skills, Industry and Regions
Year
2026
Document number
ISBN 978-1-76090-716-7
Document language
English
Source type
Government / public
Access
Free to read
Licence
CC BY 3.0: share with attribution
Original licence note

PDF p.2 states Creative Commons Attribution 3.0 Australia unless otherwise indicated; credit State of Victoria. PDF read through web reader; local curl returned 403 HTML. Round 5/6 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

State of Victoria, Department of Jobs, Skills, Industry and Regions (2026). The Sustainable Data Centre Action Plan. State of Victoria, Department of Jobs, Skills, Industry and Regions. ISBN 978-1-76090-716-7. https://djsir.vic.gov.au/__data/assets/pdf_file/0015/2502330/Sustainable-Data-Centre-Action-Plan-August-2026.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.