Technical guideFree to readYear not stated

Canovate Data Centre Catalogue (2023, Turkish)

Original title Veri Merkezi Katalog

Canovate

The Canovate 2023 Data Centre Catalogue spans 320 pages of micro, mini and maxi data centres, aisle containment, 5-250 kW precision cooling, adiabatic, chillers, monitoring and modular UPS products.

On this page

Overview

The catalogue covers the data-centre product family of Canovate, a Turkish technology group founded in 1979. The company says it manufactures on 30,000 m² of covered space in Çekmeköy, Istanbul, exports 60% of output to 72 countries and invested more than 20 million dollars in R&D between 2001 and 2016. Its timeline lists in-row coolers in 2013, micro, mini and mobile data centres in 2014, indirect evaporative adiabatic cooling in 2018 and edge data-centre solutions with redundant cooling in 2022.

Data-centre solutions come in four scales: micro (up to 4 kW cooling, IP54, 24U-47U, with in-cabinet UPS, cooling, fire suppression, PDU and environment monitoring), mini, maxi and mobile. The maxi section describes cold and hot aisle containment, a cold-aisle container with in-row cooling, hot-aisle containment with CRAC/CRAH units and indirect evaporative cooling (IEC) applications. The containment system can be retrofitted, is modular and offers fast factory-tested deployment.

The cooling systems section covers precision air conditioners (ADX SX-S on/off compressor DX series, ADX DX-D inverter compressor series), the 22.5-52 kW inverter-controlled FC52X in-row unit, 50-250 kW indirect adiabatic systems, screw and scroll compressor chillers, heat-recovery inverter screw chillers and water-cooled groups. Tables give cooling capacity, power consumption, EER, weight and dimensions.

The security and monitoring section describes a sensor-based monitoring system (up to 500 sensors on one unit with expansion modules, 4-level threshold control). The power section includes a rack-mount modular UPS with 25 kVA/25 kW power modules (scalable 30-900 kVA, 0.66 m² for 300 kVA).

Key points

  1. The micro data centre offers up to 4 kW cooling, IP54 protection and 24U-47U height options.
  2. Maxi data-centre applications combine cold and hot aisle containment with in-row and CRAC/CRAH cooling.
  3. ADX SX-S precision cooling capacity runs 10.68 to 53.96 kW; the ADX DX-D series covers 34.25-105.4 kW.
  4. The FC52X in-row unit gives 52 kW in 42U/47U cabinets; inverter control spans 22.5-52 kW with teamwork of up to 8 units.
  5. Indirect adiabatic systems cover 50-250 kW; direct free cooling and adiabatic mode are options.
  6. Screw chiller tables run 73.3 to 620 kW; heat-recovery inverter chillers 478-1178 kW (EER 3.17-3.32).
  7. The scroll CWW series covers 138.32-668.4 kW; tables are based on 12/7°C water and 35°C ambient.
  8. The monitoring system supports up to 500 sensors on one unit with expansion and 4-level threshold control.
  9. Modular UPS uses 25 kVA/25 kW modules scalable 30-900 kVA; 0.66 m² and 409 kW/m² power density at 300 kVA.

Using it in design

  • For small edge and branch rooms consider a micro or mini data centre (with in-cabinet UPS, cooling, fire and monitoring) as one ready package and write the redundant cooling option into the specification.
  • Use cold or hot aisle containment as a retrofit module in older server rooms to cut air mixing; plan layout together with in-row cooling.
  • Select precision air conditioners by capacity (10.68-105.4 kW), compressor type (on/off or inverter) and part-load range; compute annual energy from the EER and power tables.
  • In hot, dry climates evaluate indirect adiabatic (IEC) systems together with water consumption and the DX backup mode.
  • Match monitoring and UPS modularity (25 kVA modules up to 900 kVA) to the growth plan; set the N+1 module count from load growth.

Who should read it

Designers and integrators in Türkiye selecting cooling, containment, monitoring and power products for micro, mini and maxi data centres.

Document contents

  1. About Canovate Group
  2. Micro Data Centre Solutions
  3. Mini Data Centre Solutions
  4. Maxi Data Centre Solutions
  5. Cold / Hot Aisle Systems
  6. Maxi Data Centre Applications
  7. Mobile Data Centre Solutions
  8. Cooling Systems (precision, in-row, adiabatic, chillers)
  9. Data Centre Security and Monitoring
  10. Data Centre Power Solutions

Publication details

Authors
Canovate
Publisher
Canovate
Year
Year not stated
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Üreticinin herkese açık kaynağı okundu. Açık erişim yeniden dağıtım izni değildir; tam metin kütüphaneye alınmaz. Üreticinin Türkçe katalog dizininden indirildi. URL 2023 içerse de belge içinde kesin yayın tarihi doğrulanamadığından year null tutuldu.

Citation

Canovate Veri Merkezi Katalog. Canovate. https://canovate.com/catalogs/DATA-CENTER/2023-DATA-CENTER-CATALOGUE-TR.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.