Canovate Data Centre Catalogue (2023, Turkish)
Original title Veri Merkezi Katalog
Canovate
The Canovate 2023 Data Centre Catalogue spans 320 pages of micro, mini and maxi data centres, aisle containment, 5-250 kW precision cooling, adiabatic, chillers, monitoring and modular UPS products.
On this page
Overview
The catalogue covers the data-centre product family of Canovate, a Turkish technology group founded in 1979. The company says it manufactures on 30,000 m² of covered space in Çekmeköy, Istanbul, exports 60% of output to 72 countries and invested more than 20 million dollars in R&D between 2001 and 2016. Its timeline lists in-row coolers in 2013, micro, mini and mobile data centres in 2014, indirect evaporative adiabatic cooling in 2018 and edge data-centre solutions with redundant cooling in 2022.
Data-centre solutions come in four scales: micro (up to 4 kW cooling, IP54, 24U-47U, with in-cabinet UPS, cooling, fire suppression, PDU and environment monitoring), mini, maxi and mobile. The maxi section describes cold and hot aisle containment, a cold-aisle container with in-row cooling, hot-aisle containment with CRAC/CRAH units and indirect evaporative cooling (IEC) applications. The containment system can be retrofitted, is modular and offers fast factory-tested deployment.
The cooling systems section covers precision air conditioners (ADX SX-S on/off compressor DX series, ADX DX-D inverter compressor series), the 22.5-52 kW inverter-controlled FC52X in-row unit, 50-250 kW indirect adiabatic systems, screw and scroll compressor chillers, heat-recovery inverter screw chillers and water-cooled groups. Tables give cooling capacity, power consumption, EER, weight and dimensions.
The security and monitoring section describes a sensor-based monitoring system (up to 500 sensors on one unit with expansion modules, 4-level threshold control). The power section includes a rack-mount modular UPS with 25 kVA/25 kW power modules (scalable 30-900 kVA, 0.66 m² for 300 kVA).
Key points
- The micro data centre offers up to 4 kW cooling, IP54 protection and 24U-47U height options.
- Maxi data-centre applications combine cold and hot aisle containment with in-row and CRAC/CRAH cooling.
- ADX SX-S precision cooling capacity runs 10.68 to 53.96 kW; the ADX DX-D series covers 34.25-105.4 kW.
- The FC52X in-row unit gives 52 kW in 42U/47U cabinets; inverter control spans 22.5-52 kW with teamwork of up to 8 units.
- Indirect adiabatic systems cover 50-250 kW; direct free cooling and adiabatic mode are options.
- Screw chiller tables run 73.3 to 620 kW; heat-recovery inverter chillers 478-1178 kW (EER 3.17-3.32).
- The scroll CWW series covers 138.32-668.4 kW; tables are based on 12/7°C water and 35°C ambient.
- The monitoring system supports up to 500 sensors on one unit with expansion and 4-level threshold control.
- Modular UPS uses 25 kVA/25 kW modules scalable 30-900 kVA; 0.66 m² and 409 kW/m² power density at 300 kVA.
Using it in design
- For small edge and branch rooms consider a micro or mini data centre (with in-cabinet UPS, cooling, fire and monitoring) as one ready package and write the redundant cooling option into the specification.
- Use cold or hot aisle containment as a retrofit module in older server rooms to cut air mixing; plan layout together with in-row cooling.
- Select precision air conditioners by capacity (10.68-105.4 kW), compressor type (on/off or inverter) and part-load range; compute annual energy from the EER and power tables.
- In hot, dry climates evaluate indirect adiabatic (IEC) systems together with water consumption and the DX backup mode.
- Match monitoring and UPS modularity (25 kVA modules up to 900 kVA) to the growth plan; set the N+1 module count from load growth.
Who should read it
Designers and integrators in Türkiye selecting cooling, containment, monitoring and power products for micro, mini and maxi data centres.
Document contents
- About Canovate Group
- Micro Data Centre Solutions
- Mini Data Centre Solutions
- Maxi Data Centre Solutions
- Cold / Hot Aisle Systems
- Maxi Data Centre Applications
- Mobile Data Centre Solutions
- Cooling Systems (precision, in-row, adiabatic, chillers)
- Data Centre Security and Monitoring
- Data Centre Power Solutions
Publication details
- Authors
- Canovate
- Publisher
- Canovate
- Year
- Year not stated
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Üreticinin herkese açık kaynağı okundu. Açık erişim yeniden dağıtım izni değildir; tam metin kütüphaneye alınmaz. Üreticinin Türkçe katalog dizininden indirildi. URL 2023 içerse de belge içinde kesin yayın tarihi doğrulanamadığından year null tutuldu.
Citation
Canovate Veri Merkezi Katalog. Canovate. https://canovate.com/catalogs/DATA-CENTER/2023-DATA-CENTER-CATALOGUE-TR.pdf