Technical guideFree to readYear not stated

Hyper-Cool Liquid Cooling Series

Coolnet

Coolnet's Hyper-Cool catalogue covers liquid-cooling products from row CDUs and dry coolers to rear-door exchangers and immersion tanks, with model tables from 4 kW up to 2000 kW.

On this page

Overview

The Coolnet (Anhui Coolnet Data Power) catalogue presents liquid-cooled racks, CDUs, manifolds, immersion tanks, prefabricated piping and primary-side cooling sources as one product family. The integrated design of dry coolers and supplementary cooling units, with air-cooled and liquid-cooled modules sharing one cold-water circuit, is presented as the way to save cost and space.

The CDU section has three classes: row CDUs (an 11-model table, secondary circuit 40/50°C, primary circuit 32/37°C), large CDUs (HP500T, HP800T, HP1000T, HP2000T at 500, 800, 1000 and 2000 kW) and rack CDUs (HP005R, HP010R, HP020R, HP040R at 5, 10, 20 and 40 kW). All list dual-pump redundancy, a stainless plate heat exchanger, PLC control and Modbus RTU with optional TCP/IP.

For immersion, a 4 kW HPL-04 tank cabinet and CDU cabinets from DC-004 to DC-060 (4 to 60 kW) are listed. On the heat-rejection side, the dry cooler series uses SUS304 tubes, EC fans with 10-100% stepless speed and an optional spray module; its table spans 43 to 1184 kW depending on approach temperature and fluid with 380-480 V, 50/60 Hz supply.

Rear-door exchangers have a separate table: HPX250D and HPX500D are rated 25 and 50 kW at 20/28°C water and 24/38°C air. They are distinct from the neighbouring HPW800W fan wall (80 kW). In the scanned pages some height and voltage labels disagree with each other, so dimensional and electrical values should be confirmed before use.

Key points

  1. Large CDU models HP500T, HP800T, HP1000T and HP2000T exchange 500, 800, 1000 and 2000 kW; supply 3~380 V, 50 Hz.
  2. Large CDUs use 32/37°C on the primary and 40/50°C on the secondary circuit; unit weights are 750, 880, 1020 and 1250 kg.
  3. Rack CDUs HP005R, HP010R, HP020R and HP040R are 5, 10, 20 and 40 kW; 1~220 V, 50 Hz; 40, 48, 95 and 120 kg.
  4. The dry cooler table covers four models (including DHWA600-100W and DHWA1200-125W) with capacity of 43 to 1184 kW depending on approach temperature and fluid; fan power runs from 2 to 35.2 kW.
  5. EC axial fans give 10-100% stepless speed control; tubes and all fluid-contact parts are SUS304.
  6. In the integrated chiller section the dry cooler outlet water sits about 7-8°C above ambient; with 40°C outlet water and ambient below 32°C the dry cooler runs alone.
  7. HPX250D and HPX500D rear doors are 25 and 50 kW at 20/28°C water and 24/38°C air; the HPW800W fan wall is 80 kW.
  8. Manifold branch flow unevenness is stated as under 10%.

Using it in design

  • When selecting a CDU, compare the primary (32/37°C) and secondary (40/50°C) temperatures with the project's real fluid temperatures; capacity is stated for those conditions.
  • Do not mix the rear-door (HPX) and fan-wall (HPW) tables; each rests on its own capacity and power table.
  • Because height and voltage labels in the scanned pages are inconsistent, take dimensions and electrical values only with written confirmation from the manufacturer.
  • For the integrated cold station, check the annual distribution of hours above 32°C, when the supplementary chiller starts.
  • Show CDU dual-pump redundancy as its own line in the redundancy (N+1) scheme.

Who should read it

Mechanical engineers designing liquid-cooled high-density data centres and specialists selecting CDUs, dry coolers and rear-door exchangers.

Document contents

  1. Company profile
  2. Row type liquid cooling CDU
  3. Large and rack-mounted CDU
  4. Immersion liquid cooling solution
  5. Prefabricated piping and manifold
  6. Dry cooler
  7. Chilled water rear door heat exchanger and mini fan wall
  8. Integrated chiller

Publication details

Authors
Coolnet
Publisher
Coolnet
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Coolnet Hyper-Cool Liquid Cooling Series. Coolnet. https://www.coolnetpower.pl/downloads/coolnet-hyper-cool-2027.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.