Performance and Fault Tolerance Analysis in Cloud Computing Network Topologies

Original title Bulut Bilişim Ağ Topolojilerinde Performans ve Hata Toleransı Analizi

Uluslararası Sürdürülebilir Mühendislik ve Teknoloji Dergisi · Hüseyin Taner Gökmen, Mevlüt Ersoy

A 2025 simulation study from Süleyman Demirel University compares Fat Tree, Z-Fat Tree and RUFT-PL at k=8: RUFT-PL gives the lowest mean latency (7.26 ms) and keeps over 95% success at 60% link failures.

On this page

Overview

The paper compares three multilayer switch-centric topologies preferred in data centres (Fat Tree, Z-Fat Tree and RUFT-PL) for packet delivery success, latency and resilience to link failures. Fat Tree is a symmetric structure of k-port switches: k pods, k/2 edge and k/2 aggregation switches per pod, (k/2)^2 core switches and k^3/4 servers. Z-Fat Tree limits the links between edge and aggregation layers by patterns (full, cross, diagonal, upper and lower triangle), reducing link count, hardware cost and energy use. RUFT-PL (Reduced Unidirectional Fat Tree with Parallel Links) supports each edge-aggregation and aggregation-core connection with several parallel physical links.

The method uses Python and the NetworkX library. Each topology is built with k=8. A shortest path is found between a randomly chosen source and destination at the edge layer and total latency computed. A share of links between 0% and 60% is disabled at random, and each scenario is run with 100 or 1000 repetitions to evaluate latency distribution, success rate and robustness statistically. Without failures all three topologies reach 100% success, but their latency distributions differ.

On latency, Fat Tree shows a balanced distribution: mean 7.71 ms with most runs between 6 and 9 ms. Z-Fat Tree (full pattern) has similar success but a wider, right-shifted and less predictable distribution. RUFT-PL gives the lowest mean latency (7.26 ms) thanks to parallel links. Under failures, Fat Tree keeps high success up to 30% failure, drops quickly from 40% and falls below 45% at 70%. Z-Fat Tree is likewise stable to 30% and drops noticeably from 40%. RUFT-PL keeps success above 95% up to a 60% failure rate.

The authors conclude that parallel links raise fault tolerance, fully connected structures give balanced performance, and low link density raises failure sensitivity. The study is a simulation at k=8 only; the authors name different switch port counts (such as 12, 16, 20) and additional topologies as future work. The results are shortest-path simulation on a topology graph, not application-level traffic or hardware measurement.

Key points

  1. Compared topologies: Fat Tree, Z-Fat Tree (link-reduced by patterns) and RUFT-PL (parallel links); simulation at k=8 in Python and NetworkX.
  2. Fat Tree formulas: k pods, k/2 edge and k/2 aggregation switches per pod, (k/2)^2 core switches, k^3/4 servers.
  3. Without failures, packet delivery success is 100% for all three topologies.
  4. Mean latency: Fat Tree 7.71 ms (mostly 6-9 ms), RUFT-PL 7.26 ms (lowest); Z-Fat Tree distribution wider and right-shifted.
  5. Link failures from 0% to 60% were applied at random, with 100 or 1000 repetitions per scenario.
  6. Fat Tree keeps high success up to 30% failure, drops quickly from 40% and falls below 45% at 70%.
  7. Z-Fat Tree is also stable to 30% and drops noticeably at 40%.
  8. RUFT-PL keeps success above 95% up to a 60% failure rate.
  9. The authors name scalability analysis with higher switch port counts (12, 16, 20) as future work.

Using it in design

  • When choosing a fabric topology, look beyond nominal bandwidth to reachability under random link loss; make the success-versus-failure curve a comparison criterion.
  • Evaluate adding parallel links (via LAG or ECMP) between leaf-spine and spine-core tiers for resilience to partial link loss.
  • Weigh the cost and energy gains of link-reducing patterns (such as Z-Fat Tree) against their higher sensitivity at high failure rates.
  • Note in the design rationale that this study is a k=8 simulation, and re-simulate or model for your own port count and scale.
  • For service-continuity-critical systems, add a random link-failure scenario to acceptance testing.

Who should read it

Architects, academics and students selecting and analysing data-centre network topologies for resilience.

Document contents

  1. Introduction
  2. Cloud computing models
  3. Cloud computing network topologies: Fat Tree, Z-Fat Tree, RUFT-PL
  4. Research findings: latency distributions, success rate under link failure
  5. Discussion and conclusion
  6. References

Publication details

Authors
Hüseyin Taner Gökmen; Mevlüt Ersoy
Publisher
Uluslararası Sürdürülebilir Mühendislik ve Teknoloji Dergisi
Year
2025
Document number
9(1), 58–69
Document language
Turkish
Source type
Scientific
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public source inspected. No document-specific redistribution permission established; metadata and original brief summaries only. Local downloads are research evidence, not a redistribution package.

Citation

Hüseyin Taner Gökmen; Mevlüt Ersoy (2025). Bulut Bilişim Ağ Topolojilerinde Performans ve Hata Toleransı Analizi. Uluslararası Sürdürülebilir Mühendislik ve Teknoloji Dergisi. 9(1), 58–69. https://doi.org/10.62301/usmtd.1703696

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.