RFC 9786: EVPN Port-Active Redundancy Mode

IETF / RFC Editor · P. Brissette, LA. Burdet et al.

An IETF Standards Track RFC (June 2025) adding a 'Port-Active' interface-level active/standby multihoming mode to EVPN, removing the need for ICCP and LDP.

On this page

Overview

RFC 7432 defines Single-Active and All-Active multihoming for EVPN-based multi-chassis link aggregation (MC-LAG). All-Active gives per-flow load balancing; Single-Active keeps one PE active per service. RFC 9786 adds a mode for cases where interface-level active/standby multihoming is needed. The primary consideration is deterministic forwarding through a specific interface rather than statistical per-flow balancing across multiple PEs; certain QoS features need this, and fast convergence is expected.

In Port-Active mode only one of the two interfaces attached to a customer equipment (CE) forwards, and the other is on standby; all services on an interface are active or standby together. The Ethernet Segment Identifier (ESI) is assigned per access interface, which may be L2 or L3. The active PE is chosen by the Designated Forwarder (DF) election of RFC 8584, performed per [ES] instead of per [ES, Ethernet Tag]. Modulo, highest random weight (HRW) and preference-based algorithms are described, and a Port Mode bit (bit 5) is added to the DF Election Capabilities.

Non-DF PEs apply bidirectional blocking for all traffic comparable to Single-Active mode; they may keep the interface operationally down or, when LACP runs, set the LACP state to Out of Sync for better convergence during standby-to-active transition. The primary/backup bits of the EVPN L2 Attributes community are used to improve convergence.

The RFC states that the solution is fully compliant with RFC 7432 and needs no new protocol enhancements to existing EVPN RFCs. It is independent of the MPLS, VXLAN or SRv6 underlay. It replaces legacy ICCP-based MC-LAG and supports 1+N redundancy efficiently with a BGP route reflector, whereas ICCP needs a full mesh of LDP sessions among PEs in the redundancy group.

Key points

  1. Published in June 2025 on the Standards Track; adds an interface-level active/standby mode to the Single-Active and All-Active modes of RFC 7432.
  2. Rationale: deterministic forwarding through a specific interface, needed by some QoS features, with fast convergence.
  3. Only one interface forwards at a time, and all services on that interface are active together.
  4. ESI is assigned per access interface (auto-derived or manual); the interface may be L2 or L3.
  5. DF election is per [ES]; modulo, HRW and preference-based algorithms apply; a Port Mode bit (bit 5) is added to DF Election Capabilities.
  6. A non-DF PE may keep the interface down or, with LACP, set the state to Out of Sync, which converges better on transition.
  7. Port Mode cannot be combined with AC-Influenced DF: the AC-DF bit must be 0 when Port Mode is advertised.
  8. No ICCP or LDP needed; independent of MPLS, VXLAN or SRv6 and supports 1+N redundancy with a BGP route reflector.

Using it in design

  • Consider Port-Active instead of All-Active when server or storage attachment needs deterministic QoS or single-interface active/standby behaviour.
  • For Port-Active, document the ESI assignment scheme (auto or manual) and the DF election algorithm for each access interface.
  • On LACP attachments, test the option of setting the standby PE to LACP Out of Sync instead of bringing the interface down, against convergence targets.
  • When migrating legacy ICCP-based MC-LAG to EVPN Port-Active, account for the removal of the LDP dependency and for route reflector capacity.
  • Add Port Mode DF Election Capability support to the device compliance list.

Who should read it

Network architects designing EVPN multihomed server, storage or WAN attachment, and engineers migrating from MC-LAG to EVPN.

Document contents

  1. Introduction: requirements language, Multi-Chassis Link Aggregation (MC-LAG)
  2. Port-Active Redundancy Mode: overall advantages, procedures
  3. Designated Forwarder Algorithm to Elect per Port-Active PE: capability flag, modulo, HRW, preference-based, AC-influenced DF election
  4. Convergence Considerations: primary/backup bits per Ethernet Segment, backward compatibility
  5. Applicability
  6. IANA and Security Considerations

Related standards

  • RFC 9786

Publication details

Authors
P. Brissette; LA. Burdet; B. Wen; E. Leyton; J. Rabadan
Publisher
IETF / RFC Editor
Year
2025
Document number
RFC 9786
Document language
English
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.

Citation

P. Brissette; LA. Burdet; B. Wen; E. Leyton; J. Rabadan (2025). RFC 9786: EVPN Port-Active Redundancy Mode. IETF / RFC Editor. RFC 9786. https://doi.org/10.17487/RFC9786

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.