RFC 10039: Interconnecting EVPN and IPVPN Domains
IETF / RFC Editor · J. Rabadan, A. Sajassi et al.
An IETF Standards Track RFC (September 2026) defining interworking for tenant networks that span EVPN and IPVPN domains, plus the D-PATH BGP attribute that prevents control-plane loops at gateway nodes.
On this page
Overview
EVPN provides a unified BGP control plane for intra- and inter-subnet forwarding in tenant networks. When a tenant network spans domains using EVPN and others using the VPN-IPv4/VPN-IPv6 (IPVPN) address families, interworking procedures are needed for end-to-end connectivity. The RFC covers interconnecting two EVPN domains, two IPVPN domains, or an EVPN with an IPVPN domain, and governs re-origination of EVPN Route Type 2 and Route Type 5 prefixes.
The central concept is the Interworking PE. It imports routes from one domain, installs them in an IP-VRF and re-originates them with the encapsulation attributes of the adjacent domain, making the solution independent of the transport encapsulation in each domain. Nodes may act as composite PEs, gateway PEs, or both, with separate procedures for each role.
When redundant gateway PEs connect different domains, control-plane loops can form if routes are redistributed without safeguards. The RFC defines a new BGP path attribute, Domain Path (D-PATH), carrying domain identifiers (6-octet DOMAIN-ID) and an ISF_SAFI_TYPE for domain-level loop detection. D-PATH alters BGP best-path selection for SAFI 128 (IPVPN) and 70 (EVPN) routes and updates RFC 4271 procedures only for those families.
Two modes govern propagation of path attributes across domains: the default No Propagation mode and Uniform Propagation mode. In No Propagation mode D-PATH is not propagated and redundant gateways may remain exposed to loops; the RFC notes that routing policy or the Route Origin community can mitigate this but cannot guarantee coverage of every case. The document also covers error handling, security and IANA considerations.
Key points
- Published in September 2026 as a Proposed Standard; the D-PATH BGP attribute prevents inter-domain control-plane loops.
- Scope: two EVPN, two IPVPN, or an EVPN and IPVPN domain; ISF routes use SAFI 128 (IPVPN) and 70 (EVPN).
- An Interworking PE imports routes, installs them in an IP-VRF and re-originates them with the neighbouring domain's encapsulation parameters.
- D-PATH domain segment: 1-octet length, Last Domain and Domain of Origin; each domain is a 6-octet DOMAIN-ID (4-octet Global Administrator plus 2-octet Local Administrator) and an ISF_SAFI_TYPE.
- D-PATH changes BGP best-path selection for SAFI 128 and 70; RFC 4271 is updated only for those families and only when D-PATH is used.
- No Propagation mode is the default and does not propagate D-PATH; Uniform Propagation copies a limited set of common attributes and discourages indiscriminate copying for security reasons.
- D-PATH may appear only once in an update message.
- Composite PE and gateway PE procedures are specified in separate sections, and a use case combining both roles is covered.
Using it in design
- For a mixed EVPN and IPVPN tenant network across several data centres or WAN providers, decide in the design which nodes are Interworking PEs and whether they are composite or gateway.
- Add D-PATH support to hardware and software selection criteria for redundant gateway PEs; if No Propagation mode is chosen, document how loop risk is handled by policy.
- Define a naming scheme that assigns a unique DOMAIN-ID to every domain, especially when several operators are involved.
- Document with an explicit table which SAFI each inter-domain route is exported with and which attributes are copied (Uniform Propagation).
- Verify gateway redundancy in commissioning with the loop scenario (route imported at one gateway and re-advertised by the other).
Who should read it
Network architects and BGP engineers designing multi-domain data-centre interconnects and EVPN-to-IPVPN handoffs.
Document contents
- Introduction and Problem Statement
- Terminology and Interworking PE Components
- Domain Path (D-PATH) Attribute
- BGP Path Attribute Propagation Across Domains: No Propagation Mode, Uniform Propagation Mode, Aggregation of Routes
- Route Selection Process for ISF Routes: Tie-Breaking and Selection Rules, Examples
- Composite PE Procedures
- Gateway PE Procedures: Export Conditions, Advertisement Behavior
- Interworking Use Cases
- BGP Error Handling on Interworking PEs
- Security and IANA Considerations
Related standards
- RFC 10039
Publication details
- Authors
- J. Rabadan; A. Sajassi; J. Drake; W. Lin; J. Uttaro; A. Simpson
- Publisher
- IETF / RFC Editor
- Year
- 2026
- Document number
- RFC 10039
- Document language
- English
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
The document copyright notice identifies IETF Trust Legal Provisions (BCP 78). Full-text redistribution and adaptation conditions were not separately audited; this deliverable is metadata and original summary only.
Citation
J. Rabadan; A. Sajassi; J. Drake; W. Lin; J. Uttaro; A. Simpson (2026). RFC 10039: Interconnecting EVPN and IPVPN Domains. IETF / RFC Editor. RFC 10039. https://doi.org/10.17487/RFC10039
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
