Technical guideFree to read2026

Google Data Centers: Operating sustainably (energy and water)

Google

Google's page on its data centre energy and water strategy; water cooling is chosen where it lowers energy and carbon, balanced against local water risk.

On this page

Overview

This Google page summarises its data centre energy and water strategy. The central principle is that water cooling is chosen where it lowers energy and carbon compared with air-cooled chillers, with the trade-off evaluated per campus and balanced against local water risk and the use of non-potable sources. The page also restates fleet PUE and the net-zero and 24/7 CFE goals.

Water metrics: 87% of 2025 freshwater withdrawal came from sources at low or medium depletion/scarcity risk. Water stewardship projects replenished about 7.7 billion gallons in 2025, roughly 78% of freshwater consumption. On energy, more than 240 agreements for about 35 GW of new clean energy were signed in 2010-2025, with over 12 GW contracted in 2025 alone. Withdrawal and replenishment are different quantities; the replenishment share is set against consumption, not withdrawal.

The climate target is to cut combined Scope 1, Scope 2 (market-based) and Scope 3 emissions by 50% versus 2019 by 2030. The figures are the company's statements and the 87% share is withdrawal-based, so it is not directly comparable with consumption-based WUE. The page illustrates that an evaporative cooling decision must weigh its PUE gain against its water cost. Related standards are ISO/IEC 30134-9 and the GHG Protocol.

Key points

  1. 87% of 2025 freshwater withdrawal from sources at low or medium depletion/scarcity risk.
  2. Water stewardship projects replenished about 7.7 billion gallons in 2025 (about 78% of freshwater consumption).
  3. More than 240 agreements for about 35 GW of new clean energy in 2010-2025; over 12 GW contracted in 2025.
  4. 2030 net-zero target: cut combined Scope 1, 2 (market-based) and 3 emissions 50% versus 2019.
  5. Water cooling is chosen where it reduces energy/carbon versus air-cooled chillers; trade-off evaluated per campus.

Using it in design

  • Compare PUE and WUE for each site and document the energy–water trade-off using a water-stress measure, such as a WRI Aqueduct category.
  • Prioritise non-evaporative cooling in high-water-stress sites and document the reason for any different selection.
  • When showing WUE, label whether it is withdrawal-based or consumption-based.

Who should read it

Designers balancing energy against water while choosing a cooling technology.

Related standards

  • ISO/IEC 30134-9
  • GHG Protocol

Publication details

Authors
Google
Publisher
Google
Year
2026
Document language
English
Source type
Expert / community
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document

Citation

Google (2026). Google Data Centers: Operating sustainably (energy and water). Google. https://datacenters.google/operating-sustainably/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.