StandardPaid2024

Low-voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects

IEC · IEC TC 64

IEC 60364-4-42:2024 is the fourth edition of the part on protecting persons, livestock and property from the thermal effects of electrical installations. It is now designated a group safety publication (GSP).

This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

The standard addresses protection against the thermal effects of electrical installations. Its scope covers burns from electrical equipment, the risk of combustion or degradation of materials, flame propagation between fire compartments segregated by barriers, and impairment of the safe functioning of equipment, including safety services, due to thermal effects. This record rests on the publisher's public catalogue abstract and product metadata; the full text of the paid standard was not read.

Edition 4 was published on 22 November 2024 and runs to 64 pages. It replaces the 2010 edition and Amendment 1:2014. Another notable change is that the standard is now designated a group safety publication (GSP) under IEC Guide 104 and ISO/IEC Guide 51, giving it a framework role for other standards on safety matters.

The topic matters in data centers because dense cabling, busbar systems and power distribution equipment cross fire compartments and generate heat. The standard covers the principle of limiting fire spread where cable routes cross compartment boundaries, and the risk of heat-related burns on accessible equipment surfaces.

As a limit, the abstract does not include detailed temperature limits or compartment requirements; for these, consult the standard itself and the relevant national fire regulations. The related sources in the record are IEC 60364-5-52 and the Turkish Binaların Yangından Korunması Hakkında Yönetmelik.

Key points

  1. Covers protection against thermal effects, risk of combustion or degradation of materials, and burns from electrical equipment.
  2. Covers flames propagating from electrical installations to other fire compartments segregated by barriers.
  3. Covers impairment of safe functioning of equipment, including safety services, due to thermal effects.
  4. A group safety publication (GSP) per IEC Guide 104 / ISO/IEC Guide 51.
  5. Edition 4 published 2024-11-22, 64 pages.
  6. Replaces the 2010 edition and Amendment 1:2014.
  7. Paid standard; the record is based on the catalogue abstract only.

Using it in design

  • When cable routes cross fire-compartment boundaries, require a fire-stopping element and warn if it is missing.
  • Tag equipment surface temperatures where operators can reach them.
  • Add an electrical-to-fire interface check to design review.
  • Assess local requirements together with the Turkish Binaların Yangından Korunması Hakkında Yönetmelik.

Who should read it

Engineers designing data center electrical installations, fire safety consultants, and design reviewers.

Related standards

  • IEC 60364-5-52
  • Binaların Yangından Korunması Hakkında Yönetmelik

Publication details

Authors
IEC TC 64
Publisher
IEC
Year
2024
Document number
IEC 60364-4-42:2024
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

IEC TC 64 (2024). Low-voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects. IEC. IEC 60364-4-42:2024. https://webstore.iec.ch/en/publication/65121

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.