Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, and definitions

IEC · IEC TC 64

The top-level part of the IEC 60364 low-voltage installation series, defining its scope and fundamental safety requirements; sixth edition published in 2025.

This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

IEC 60364-1 is the top-level part of the IEC 60364 series on low-voltage electrical installations. It defines the scope and objective of the series and the fundamental safety requirements an electrical installation must meet, which makes it the framework document on which the other parts rest. The sixth edition, published on 5 September 2025, runs to 99 pages and was prepared by IEC TC 64.

The new edition cancels and replaces the 2005 fifth edition, and the entire document has been restructured and renumbered. New topics include safety services and standby electric supply systems (1.5.2.2.2), energy efficiency (1.5.2.14) and prosumer electrical installations (1.5.2.15). In addition, clause 1.5.4.3 recommends periodic verification of protective measures over the lifetime of the installation.

Related documents include IEC 60364-4-41, IEC 60364-5-56, HD 60364-1 and the Turkish Elektrik İç Tesisleri Yönetmeliği. Its limit is that it does not give detailed design rules; those sit in the later parts of the series, which this page does not replace.

Key points

  1. Defines the scope and objective of the IEC 60364 series and fundamental safety requirements.
  2. Sixth edition cancels and replaces the 2005 fifth edition; restructured and renumbered.
  3. 1.5.2.2.2 adds safety services and standby electric supply systems.
  4. 1.5.2.14 adds energy efficiency.
  5. 1.5.2.15 adds prosumer electrical installations.
  6. 1.5.4.3 recommends periodic verification of protective measures over the installation lifetime.
  7. Published 5 September 2025; 99 pages, IEC TC 64.

Using it in design

  • In the electrical assessment, use IEC 60364-1 as the root of the low-voltage rule set.
  • Capture the earthing system (TN/TT/IT) and supply characteristics at project start.
  • Record standby and safety-service supplies as distinct source types, because the series treats them differently.
  • Reflect the periodic verification recommendation in the operations maintenance plan.

Who should read it

Electrical engineers designing low-voltage installations and standards compliance leads.

Related standards

  • IEC 60364-4-41
  • IEC 60364-5-56
  • HD 60364-1
  • Elektrik İç Tesisleri Yönetmeliği

Publication details

Authors
IEC TC 64
Publisher
IEC
Year
2025
Document number
IEC 60364-1:2025
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

IEC TC 64 (2025). Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, and definitions. IEC. IEC 60364-1:2025. https://webstore.iec.ch/en/publication/63699

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.