Low-voltage switchgear and controlgear assemblies - Part 1: General rules
IEC · IEC TC 121
General rules for low-voltage switchgear and controlgear assemblies: definitions, service conditions, construction, technical characteristics and design/routine verification.
This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
IEC 61439-1 lays down the general rules for low-voltage switchgear and controlgear assemblies. It covers definitions, service conditions, construction requirements, technical characteristics and verification requirements. Prepared by IEC TC 121, its third edition was published on 5 May 2020, with corrigenda in 2021 and 2023. In Turkey it is applied as TS EN 61439-1.
Conformity of an assembly is judged not with this general part but with the relevant product part (Part 2 onwards); Part 2 applies to assemblies not covered by Part 3 onward. The 2020 edition introduced group rated current for circuits within a loaded assembly and refocused temperature-rise verification on it. It also added DC requirements and the concept of class I and class II assemblies.
The standard clarifies that UPS, converters, SMPS and drives built into an assembly are tested to their own product standards, while their incorporation follows IEC 61439.
Key points
- Lays down definitions, service conditions, construction requirements, technical characteristics and verification requirements for LV assemblies.
- Conformity is determined with the relevant part 2 onward; Part 2 applies to assemblies not covered by Part 3 onward.
- Group rated current is introduced for circuits within a loaded assembly; temperature-rise verification is refocused on it.
- DC requirements are added.
- The concept of class I and class II assemblies is added.
- UPS, converters, SMPS and drives are tested to their own product standards; their incorporation follows IEC 61439.
- Edition 3 was published 2020-05-05 (504 pages incl. redline); corrigenda 2021 and 2023.
- Related documents: IEC 61439-2, IEC 61439-6, EN 61439-1, TS EN 61439-1.
Using it in design
- In the switchboard catalogue, store the assembly's rated current (InA), the group rated current or rated diversity factor per circuit, Icw/Ipk and the form of separation.
- Check that the summed loading of outgoing circuits respects the group rating rather than the sum of nameplate values.
- Mark UPS cabinets as separate products, not as assemblies.
Who should read it
Electrical engineers designing boards and distribution systems, panel builders and specification writers.
Related standards
- IEC 61439-2
- IEC 61439-6
- EN 61439-1
- TS EN 61439-1
Publication details
- Authors
- IEC TC 121
- Publisher
- IEC
- Year
- 2020
- Document number
- IEC 61439-1:2020
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
IEC TC 121 (2020). Low-voltage switchgear and controlgear assemblies - Part 1: General rules. IEC. IEC 61439-1:2020. https://webstore.iec.ch/en/publication/67026
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.