Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC · IEC TC 64
The core low-voltage safety part that sets essential requirements for protection against electric shock of persons and livestock and the conditions for additional protection such as RCDs.
This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
IEC 60364-4-41 is the core safety part of the low-voltage electrical installations series, dealing with protection against electric shock. It specifies essential requirements for protecting persons and livestock. The version described here is the consolidated text merging the 2005 fifth edition and Amendment 1 (2017), and it includes the February 2018 corrigendum. This page rests on the publisher's public catalogue abstract.
The standard deals with the application of these requirements and their coordination in relation to external influences. In other words, the choice of protective measure does not stand apart from the conditions of the environment where the installation sits. It also gives requirements for additional protection in certain cases, with residual current devices (RCDs) as the typical example.
The consolidated text runs to 152 pages, and a new edition is in preparation per its lifecycle. Related documents include IEC 60364-4-43, IEC 60364-5-54 and HD 60364-4-41, covering overcurrent protection, earthing arrangements and the European harmonised text respectively.
Consult the standard itself for those values.
Key points
- Specifies essential requirements for protection against electric shock of persons and livestock.
- Deals with application and coordination of the requirements in relation to external influences.
- Gives requirements for additional protection in certain cases.
- Consolidated version: edition 5 (2005) plus Amendment 1 (2017), with the February 2018 corrigendum included.
- 152 pages; a new edition is in preparation.
- Related documents: IEC 60364-4-43, IEC 60364-5-54, HD 60364-4-41.
- The standard is paid; the full text is not redistributed.
Using it in design
- Calculate fault-loop impedance for every final and distribution circuit, and verify automatic disconnection times for the selected earthing system.
- Flag circuits that need additional RCD protection.
- Treat this as a hard check that must pass before cable sizing is accepted.
Who should read it
Electrical engineers designing low-voltage distribution for data centres, and electrical safety reviewers.
Related standards
- IEC 60364-4-43
- IEC 60364-5-54
- HD 60364-4-41
Publication details
- Authors
- IEC TC 64
- Publisher
- IEC
- Year
- 2017
- Document number
- IEC 60364-4-41:2005+AMD1:2017
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
IEC TC 64 (2017). Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock. IEC. IEC 60364-4-41:2005+AMD1:2017. https://webstore.iec.ch/en/publication/60169
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.