Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
IEC · IEC TC 64
The low-voltage standard on selecting and erecting cables, busbar trunking and powertrack, covering current-carrying capacity, harmonics, voltage drop and maintainability.
This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
IEC 60364-5-52 is the part of the IEC 60364 low-voltage installation series that deals with the selection and erection of wiring systems. This consolidated version (edition 3.1) combines the 2009 third edition with Amendment 1 of 2024. It was published on 22 November 2024 and runs to 177 pages. The source is a paid standard, and this summary relies only on the publisher's public catalogue abstract.
The standard covers the selection and erection of cables, busbar trunking systems and powertrack systems. Topics with a direct effect on design, such as current-carrying capacity tables, harmonics, voltage drop and maintainability, are treated within this frame. Clause 521.4 concerns busbar trunking and powertrack, 523.6 cable sizing where harmonic currents are present, and 523.9 single-core cables with metallic covering.
Clause 525 on voltage drop ties the maximum drop between the origin of the installation and the equipment to the limits in the relevant annex. Clause 528 deals with the proximity of underground power and telecommunication cables. In data centres, harmonic effects and voltage drop are leading drivers of cable selection because of high load density and non-linear IT loads. The standard's limit is that it concerns wiring systems; matters such as protective device coordination or switchboard design belong to other parts. Related documents include IEC 60364-4-43, IEC 61439-6 and HD 60364-5-52.
Key points
- Covers selection and erection of wiring systems (cables, busbar trunking, powertrack).
- Addresses current-carrying capacity tables, harmonics, voltage drop and maintainability.
- 521.4: busbar trunking and powertrack systems.
- 523.6: cable sizing where harmonic currents are present; 523.9: single-core cables with metallic covering.
- Clause 525: maximum voltage drop between installation origin and equipment, limited per the relevant annex.
- Clause 528: proximity of underground power and telecommunication cables.
- Consolidated edition 3.1 published 2024-11-22 (177 pages) combines the 2009 edition and the 2024 amendment.
Using it in design
- In the cable sizing study, base ampacity on installation-method tables with grouping and temperature derating.
- Apply harmonic derating per 523.6.
- Check voltage drop against the annex limits.
- Include busway as an alternative wiring system with its own rating data.
Who should read it
Electrical design engineers who select cables and busway for data centre low-voltage distribution.
Related standards
- IEC 60364-4-43
- IEC 61439-6
- HD 60364-5-52
Publication details
- Authors
- IEC TC 64
- Publisher
- IEC
- Year
- 2024
- Document number
- IEC 60364-5-52:2009+AMD1:2024
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
IEC TC 64 (2024). Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems. IEC. IEC 60364-5-52:2009+AMD1:2024. https://webstore.iec.ch/en/publication/103734
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
