StandardPaid2024

Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO)

IEC · IEC TC 121

The IEC 61439 product part for small final distribution boards that ordinary persons may operate (switching, replacing fuse-links); the 2024 second edition replaces the 2012 edition.

This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

IEC 61439-3:2024 is the product part of the low-voltage assemblies family devoted to distribution boards that ordinary persons may operate (DBO). Such persons can perform switching and replace fuse-links. Typical examples are small final distribution boards. The second edition was published on 26 March 2024, runs to 130 pages and replaces the 2012 edition; a commented version is also available.

The scope limits are clear from the publication abstract: nominal voltage to earth does not exceed 300 V AC (DC limits are under consideration). Outgoing circuits may be rated up to 125 A (Inc) and the assembly up to 250 A (InA). The outgoing circuits are fitted with protective devices such as those under IEC 60898-1, IEC 61008/61009, IEC 62606, IEC 62423 and IEC 60269-3.

This part is not read on its own; it is applied together with IEC 61439-1, which holds the general rules, and it has a Turkish counterpart as TS EN 61439-3. For power assemblies, the separate product part IEC 61439-2 applies.

Key points

  1. Covers assemblies operated by ordinary persons: switching operations and replacing fuse-links.
  2. Outgoing circuits use protective devices such as IEC 60898-1, IEC 61008/61009, IEC 62606, IEC 62423, IEC 60269-3.
  3. Nominal voltage to earth not exceeding 300 V AC; DC limits under consideration.
  4. Outgoing circuit rated current Inc <= 125 A; assembly rated current InA <= 250 A.
  5. Edition 2 published 26 March 2024 (130 pages); replaces the 2012 edition.
  6. Applied with IEC 61439-1; the Turkish counterpart is TS EN 61439-3.
  7. Power assemblies are covered separately by IEC 61439-2.

Using it in design

  • Board selection rule: allow the DBO type only for office/support-area final boards within the 250 A/125 A limits.
  • Specify IT-room boards operated only by skilled persons as PSC (Part 2) or BTS tap-offs.
  • State in board specifications which part of IEC 61439 applies.
  • Check the voltage limit: applications above 300 V AC to earth fall outside this part.

Who should read it

Electrical design engineers selecting and specifying low-voltage distribution boards.

Related standards

  • IEC 61439-1
  • IEC 61439-2
  • TS EN 61439-3

Publication details

Authors
IEC TC 121
Publisher
IEC
Year
2024
Document number
IEC 61439-3:2024
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

IEC TC 121 (2024). Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO). IEC. IEC 61439-3:2024. https://webstore.iec.ch/en/publication/93494

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.