Moving Beyond Diesel Generators: Exploring Renewable Backup Alternatives for Data Centers

Journal of Physics: Conference Series (IOP Publishing) · Viswambher Kambhampati, Andy van den Dobbelsteen et al.

A 2024 open-access TU Delft paper comparing renewable diesel (HVO), hydrogen, lithium-ion and NaS batteries and compressed air storage (CAES) for data-centre backup on energy performance, emissions and cost.

On this page

Overview

The paper, by TU Delft authors in the Journal of Physics: Conference Series (OSES 2024), compares sustainable alternatives to diesel generators for data-centre backup. Diesel generators are used for their mature technology, wide availability, high energy density and fast response, but they add greenhouse gas load. The introduction sets context: data centres consumed 205 TWh in 2018, may use about 3-13% of world electricity by 2030 and account for 2.5-3.7% of global greenhouse gas emissions.

The method is a sequential exploratory strategy: a literature review, pre-selection by power, discharge time, maturity and area, a comparison of efficiency, lifespan, specific energy and energy density, a cradle-to-grave life cycle assessment of global warming potential, and finally levelised cost of energy (LCOE) and a total cost of ownership with carbon cost (TCO2). Prices assumed are electricity 0.1 EUR/kWh, diesel 0.6 EUR/kWh and HVO 0.75 EUR/kWh. The authors note limits to generalisation from technology maturity and regional energy source and cost differences.

Findings: HVO runs in existing diesel infrastructure without modification and is less carbon-intensive; CAES offers low life-cycle emissions and operating cost but depends on geography; hydrogen storage has low efficiency but a lower LCOE than batteries; battery LCOE improves with more daily operating hours, yet extending backup to three days roughly triples battery capital and operating cost relative to other technologies. Flywheels can replace batteries for the initial start-up of a diesel generator.

Key points

  1. Technologies compared: HVO, hydrogen energy storage (HES), lithium-ion and sodium-sulfur batteries, compressed air energy storage (CAES), plus flywheels.
  2. For existing data centres the best option is HVO: a drop-in for conventional diesel, compatible with existing infrastructure and less carbon-intensive.
  3. For new facilities CAES is recommended where geography allows, with HES as the alternative; CAES offers low life-cycle emissions and operating cost.
  4. As backup duration grows, battery capital and operating costs rise sharply, unlike technologies where only fuel cost rises; at three days they roughly triple.
  5. Price assumptions: electricity 0.1 EUR/kWh, diesel 0.6 EUR/kWh, HVO 0.75 EUR/kWh.
  6. Carbon price needed to match diesel LCOE is 1,114.81 to 2,000 EUR/tonne for lithium-ion and 371 EUR/tonne for HES.
  7. Hydrogen systems have high specific energy but low energy density and low efficiency.
  8. Data centres used 205 TWh in 2018 and may reach about 3-13% of world electricity by 2030.

Using it in design

  • For carbon reduction at an existing diesel-backed site, first assess HVO compatibility (manufacturer approval, fuel storage); it needs no infrastructure change.
  • In new-build backup storage selection, treat backup duration (hours and days) as the primary variable and write the rapid rise in battery cost with duration into the cost model.
  • Check the area constraint (battery or hydrogen storage footprint) in the site plan against backup duration.
  • Evaluate hybrid concepts such as a flywheel or battery bridging the start of a diesel generator.
  • Include a carbon price in TCO so alternatives are compared with diesel on the same basis.

Who should read it

Designers, energy consultants and investment decision makers setting data-centre backup power and sustainability strategy.

Document contents

  1. Introduction
  2. Methodology
  3. Energy performance assessment
  4. Environmental impact assessment
  5. Financial assessment
  6. Conclusion and discussion

Publication details

Authors
Viswambher Kambhampati; Andy van den Dobbelsteen; Joep Schild
Publisher
Journal of Physics: Conference Series (IOP Publishing)
Year
2024
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Licence CC-BY-4.0 stated on publisher landing page (fetched 2026-11-16); matches Crossref licence metadata. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Viswambher Kambhampati; Andy van den Dobbelsteen; Joep Schild (2024). Moving Beyond Diesel Generators: Exploring Renewable Backup Alternatives for Data Centers. Journal of Physics: Conference Series (IOP Publishing). https://doi.org/10.1088/1742-6596/2929/1/012008

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.