Information technology - Data centres - Key performance indicators - Part 1: Overview and general requirements
ISO/IEC · ISO/IEC JTC 1
The umbrella part of the ISO/IEC 30134 series, fixing the common structure, vocabulary and boundary conditions that all resource-usage KPIs such as PUE must follow.
This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
ISO/IEC 30134-1 is the first and framework part of the series of key performance indicators (KPIs) that measure resource usage effectiveness and efficiency in data centres. The first edition, developed by ISO/IEC JTC 1 and published in 2016, runs to 11 pages. It fixes a common structure for the other parts; the series includes PUE, REF, ITEEsv, ITEUsv, ERF, CER, CUE and WUE, and every one of them must follow the rules set here.
The standard defines terminology and boundary conditions for the KPIs, and sets out the common requirements and common objectives that each individual KPI part builds on. It also gives general guidance on use. In practice this part is the reference for how a data centre boundary and its measurement points are defined before any KPI is reported, so that values from different facilities can be compared on the same footing.
The document is a paid standard and only the publisher's public catalogue abstract and product data were used here; the full text was not read. It provides no calculation method or numeric limit of its own, since that is the job of the individual KPI parts. It is therefore cited to state which boundary a given indicator was calculated on, while values come from the relevant indicator part.
Key points
- Specifies a common structure for all other parts of ISO/IEC 30134.
- Defines terminology and boundary conditions for KPIs of data centre resource usage effectiveness and efficiency.
- Sets the common requirements and objectives on which each individual KPI part builds.
- The series covers PUE, REF, ITEEsv, ITEUsv, ERF, CER, CUE and WUE.
- Edition 1 was published 2016-03-21, runs to 11 pages and was developed by ISO/IEC JTC 1.
- It is the reference for how the data centre boundary and measurement points are defined before any KPI is reported.
Using it in design
- Define the common facility boundary, measurement points and reporting period for PUE, REF, ERF, CER, CUE and WUE.
- Compute all indicators on a consistent boundary and warn when a report mixes different boundaries.
- In reports and design documents, state the measurement points and boundary used next to every indicator value.
Who should read it
Design engineers and sustainability officers who calculate, report or verify energy-efficiency indicators.
Related standards
- ISO/IEC 30134-2
- EN 50600-4-1
- ISO/IEC 22237-1
Publication details
- Authors
- ISO/IEC JTC 1
- Publisher
- ISO/IEC
- Year
- 2016
- Document number
- ISO/IEC 30134-1:2016
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
ISO/IEC JTC 1 (2016). Information technology - Data centres - Key performance indicators - Part 1: Overview and general requirements. ISO/IEC. ISO/IEC 30134-1:2016. https://webstore.iec.ch/en/publication/24432
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
