Information technology - Data centres key performance indicators - Part 2: Power usage effectiveness (PUE)

ISO/IEC · ISO/IEC JTC 1

The 2026 second edition of the international PUE standard, defining PUE, its measurement categories and reporting rules.

This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

ISO/IEC 30134-2 defines PUE (power usage effectiveness), the key performance indicator that quantifies efficient use of energy in a data centre. The second edition, published on 16 January 2026 (35 pages), supersedes the 2016 first edition. It was prepared by ISO/IEC JTC 1 and belongs to the ISO/IEC 30134 series.

The new edition introduces PUE measurement categories tied to where and how often energy is metered. The standard explains how PUE relates to infrastructure, IT equipment and IT operations, specifies measurement, calculation and reporting, and gives guidance on interpreting results correctly. A dedicated clause (Clause 9) describes PUE derivatives, for example partial and designed PUE variants.

This record was built only from the publisher's public catalogue abstract and product metadata; the full text was not read. The standard itself must be purchased for the detail of category definitions and derivative formulas. Related documents include ISO/IEC 30134-1, EN 50600-4-2 and The Green Grid WP49.

Key points

  1. PUE is defined as a KPI quantifying efficient use of energy in a data centre.
  2. Edition 2 was published 2026-01-16 (35 pages), superseding the 2016 first edition.
  3. PUE measurement categories are introduced.
  4. The standard specifies measurement, calculation and reporting of PUE.
  5. It includes guidance on correct interpretation of results.
  6. PUE derivatives are described in Clause 9.
  7. It explains PUE's relation to infrastructure, IT equipment and IT operations.
  8. Related documents: ISO/IEC 30134-1, EN 50600-4-2, The Green Grid WP49.

Using it in design

  • Calculate PUE on the annual-energy basis in the 2026 edition and identify the metering category for each result.
  • Document meter locations at utility input, UPS output, PDU output and IT input against the requirements of the measurement category.
  • Label Clause 9 derivatives (partial or design PUE) as such and never report them as plain PUE.

Who should read it

Engineers designing PUE metering and reporting, energy managers, and decision makers drafting efficiency commitments.

Related standards

  • ISO/IEC 30134-1
  • EN 50600-4-2
  • The Green Grid WP49

Publication details

Authors
ISO/IEC JTC 1
Publisher
ISO/IEC
Year
2026
Document number
ISO/IEC 30134-2:2026
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

ISO/IEC JTC 1 (2026). Information technology - Data centres key performance indicators - Part 2: Power usage effectiveness (PUE). ISO/IEC. ISO/IEC 30134-2:2026. https://webstore.iec.ch/en/publication/111538

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.