Guide to a Secure Enterprise Network Landscape (NIST SP 800-215)

Original title Guide to a Secure Enterprise Network Landscape

NIST · Ramaswamy Chandramouli

NIST's November 2022 SP 800-215 explains the limits of perimeter-based protection for enterprise networks reshaped by multi-cloud, multiple data centres and microservices, and covers microsegmentation, SDP, ZTNA and SASE.

On this page

Overview

The guide lists three drivers that changed the enterprise network: access to multiple cloud services, the geographic spread of on-premises IT resources (including multiple data centres), and microservices-based rather than monolithic applications. It aims to give secure-operations guidance for this landscape, starting with the security limits of current network access solutions.

Section two covers limits of traditional approaches: perimeter-based protection, VPN-based access, MPLS as enterprise WAN, and authentication infrastructure. Section three covers CASB, enhanced firewall capabilities, appliance sets with integrated functions, network security automation tools (monitoring, observability, automated provisioning) and networking appliances as services. Section four gives network configurations for device management, user authentication, device authentication and health monitoring, application access authorisation, and preventing attack escalation.

Section five details zero trust network access (ZTNA) as the enterprise-wide framework, and the two configurations that prevent attack escalation, microsegmentation and the software-defined perimeter (SDP), with prerequisites and implementation approaches for microsegmentation. Section six covers secure SD-WAN requirements, SD-WAN requirements for cloud access and an integrated security services architecture (SASE).

The document is enterprise-network focused and not data-centre specific, but it serves as a reference for multi-site data centre connectivity, network segmentation and management network access design.

Key points

  1. Three drivers changed the enterprise network: multi-cloud access, spread across multiple data centres and microservices-based applications.
  2. Limits of traditional approaches are covered under four headings: perimeter-based protection, VPN-based access, MPLS WAN and authentication infrastructure.
  3. Point solutions include CASB, enhanced firewall capabilities, integrated appliance sets, monitoring and observability tools and automated network provisioning.
  4. In cloud environments, network provisioning is automated with infrastructure as code (IaC) tools in DevSecOps CI/CD pipelines.
  5. Network configurations are described for four basic functions: device management, user authentication, device authentication and health monitoring, and application access authorisation.
  6. Microsegmentation divides an internal network (such as a data centre) so each segment can be monitored and controlled; prerequisites and implementation approaches have their own subsections.
  7. Within the ZTNA framework, the two configurations that prevent attack escalation are microsegmentation and the software-defined perimeter (SDP).
  8. SASE is described as a framework combining WAN with global points of presence and integrated security services.

Using it in design

  • Do not leave the data centre network protected only by a perimeter firewall; map workload inventory and traffic flows in advance for microsegmentation.
  • For management and OT access, consider identity-, device-health- and application-based authorisation (ZTNA) instead of VPN.
  • For the WAN between data centres, include SD-WAN security requirements (common and cloud access) in the specification.
  • Keep infrastructure code for network provisioning in a version-controlled, security-checked CI/CD pipeline.
  • Tie network monitoring and observability tools to threat detection.

Who should read it

Data centre and enterprise network security architects, network engineers and IT security managers.

Document contents

  1. Executive Summary
  2. Introduction
  3. Traditional Enterprise Network Access Approaches and Their Limitations
  4. Network Security Appliances in the Enterprise Network Landscape
  5. Network Configurations for Basic Security Functions
  6. Enterprise-Wide Network Security Framework: Zero Trust Network Access (ZTNA)
  7. Secure Wide Area Network Infrastructure for an Enterprise Network
  8. Summary and Conclusions

Publication details

Authors
Ramaswamy Chandramouli
Publisher
NIST
Year
2022
Document number
NIST SP 800-215
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public publisher page or document inspected. Document-specific redistribution permission was not established; metadata and original short summaries only.

Citation

Ramaswamy Chandramouli (2022). Guide to a Secure Enterprise Network Landscape. NIST. NIST SP 800-215. https://doi.org/10.6028/NIST.SP.800-215

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.