Protect Plus M400: Specifications
AEG Power Solutions
AEG Power Solutions' Protect Plus M400 is a VFI-SS-111 modular UPS family built from 10 or 15 kVA hot-swappable modules in 20-90 kVA frames, with online efficiency up to 95%.
On this page
Overview
The Protect Plus M400 product page presents AEG Power Solutions' modular double-conversion UPS family for 10-90 kVA. It is classed VFI-SS-111 under IEC 62040-3 and can be configured as 1/1, 3/1 or 3/3 phase. The power modules are 2U high and come as 10 kVA (code 30000231) or 15 kVA (code 30000230).
On the frame side, the 10 kVA module is used in 20, 40 and 60 kVA frames and the 15 kVA module in 30, 45 and 90 kVA frames. Frame dimensions are 485 x 697 x 398 mm (2U), 486 x 697 x 676 mm (4U) and 485 x 761 x 1033 mm (6U); weights are 42, 51 and 70 kg for the 20-60 kVA frames and 42, 55 and 70 kg for the 30-90 kVA frames. These figures cover the frame only; the external battery cabinet must be accounted for separately.
For performance, the page states AC/AC efficiency above 95% in double conversion and above 98% in ECO mode at nominal load, input power factor above 0.99, output power factor up to unity and a variable frequency range of 40 to 70 Hz. Modules support idle mode and cyclic operation, the static and manual bypass lines are centralised and the battery connection is common.
For scalability, up to 4 frames can run in parallel and the frames fit a 19-inch cabinet. Lead-acid and lithium-ion batteries are supported. Accessories include a battery cabinet holding 40 or 80 12 V blocks (600 x 1000 x 1600 mm, 180 kg), a 15 A external charger, a battery compensation kit, an external maintenance bypass and a remote panel. The page is promotional product data and carries no binding warranty.
Key points
- Class VFI-SS-111 modular online UPS; capacity 10-90 kVA, phase configurations 1/1, 3/1 and 3/3.
- Power modules are 2U, hot-swappable, 10 kVA or 15 kVA.
- Frame dimensions: 20/30 kVA 485 x 697 x 398 mm (2U), 40/45 kVA 486 x 697 x 676 mm (4U), 60/90 kVA 485 x 761 x 1033 mm (6U).
- Frame weights: 42 kg (20 and 30 kVA), 51 kg (40 kVA), 55 kg (45 kVA) and 70 kg (60 and 90 kVA).
- Efficiency: above 95% in double conversion and above 98% in ECO mode (nominal load).
- Input power factor above 0.99, output power factor up to unity; 50/60 Hz with a variable range of 40-70 Hz.
- Up to 4 frames operate in parallel.
- Lithium-ion compatible; battery cabinet takes 40 or 80 12 V blocks, 600 x 1000 x 1600 mm, 180 kg.
- 380/400/415 V for 3/3 configurations and 220/230/240 V for single-phase configurations.
Using it in design
- Plan load growth by module count: choose frames up to 60 kVA with 10 kVA modules or 90 kVA with 15 kVA modules, and treat the 4-frame parallel limit as the capacity ceiling.
- Calculate N+1 module counts against frame capacity; frame weights and sizes exclude the battery cabinet and external maintenance bypass, so add those to the layout separately.
- Choose battery technology early (40 or 80 lead-acid blocks, or lithium-ion); cabinet size and the 180 kg load affect floor loading and placement.
- When ECO mode is used, compare the protection class it falls back to (VFD) with load sensitivity, and put the 98% versus 95% efficiency difference into the annual energy calculation.
- Match the input and output voltage ranges (220/230/240 V and 380/400/415 V) of single-phase and 3/1 configurations to the supply and the load.
Who should read it
Electrical designers and specification engineers selecting UPS systems for small and mid-size data rooms, network rooms and critical infrastructure.
Document contents
- Overview and capacity range
- Description
- Features
- Specifications (frame models)
- Accessories
- Downloads
Publication details
- Authors
- AEG Power Solutions
- Publisher
- AEG Power Solutions
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
AEG Power Solutions Protect Plus M400: Specifications. AEG Power Solutions. https://www.aegps.com/en/product-configurator/protect-plus-m400/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.