Sollatek Maxima Online series 2-10 kVA single-phase UPS datasheet
Original title Sollatek Maxima Online 2-10kVA datasheet10911064 Oct2025 v3, pp.2-4
Sollatek
Sollatek Maxima Online is a 2, 3, 6 and 10 kVA (0.9 power factor) single-phase double-conversion UPS: 98% efficiency in ECO mode, CVCF support, up to three units in parallel.
On this page
Overview
The October 2025 datasheet presents Sollatek's Maxima Online series from 2000 VA to 10000 VA. The series is a true double-conversion design with DSP control, which gives precise output under harsh mains conditions. Listed applications include data centres, telecommunications, security and surveillance systems and multimedia equipment. It is CE compliant and certified to IEC/EN 62040.
The models are 2 kVA/1800 W, 3 kVA/2700 W, 6 kVA/5400 W and 10 kVA/9000 W, with a maximum output power factor of 0.9. Efficiency in ECO mode is stated as 98%. The input voltage range at full load is 176-300 V for the 2 and 3 kVA models and 185-275 V for the 6 and 10 kVA models; at lower input (100-176 V or 120-185 V) the UPS keeps running on mains at 40-50% load or less, but at full load it transfers to battery. Output voltage accuracy is +/-1%.
Overload limits in line mode are up to 105% continuous, up to 125% for 1 min, up to 130% for 60 s and up to 150% for 10 or 30 s, and above that 0.5 or 0.3 s. CVCF mode gives constant voltage and frequency with derating to 60% load. Parallel operation, with an optional card, allows up to three units. Communication uses an intelligent slot, USB-HID, RS232 and optional SNMP, Modbus and dry-contact cards.
Battery voltage is 48 V DC for the 2 kVA, 72 V for 3 kVA, 180 V for 6 kVA and 192 V for 10 kVA, with internal 12 V 9 Ah or 12 V 7 Ah blocks. The table gives runtimes of 28.0 min at 25% load and 2.0 min at 100% load for the 6 kVA, and 22.3 min and 1.3 min for the 10 kVA. Operating temperature is 0-40 °C, altitude up to 3000 m (derating 1% per 100 m above 1000 m) and noise below 40 to below 50 dB. Weights range from 17.4 to 63.0 kg.
Key points
- Models 2 kVA/1800 W, 3 kVA/2700 W, 6 kVA/5400 W and 10 kVA/9000 W; output PF up to 0.9.
- 98% efficiency in ECO mode; true double conversion with DSP control.
- Input at full load: 176-300 V for 2-3 kVA, 185-275 V for 6-10 kVA; frequency range 40-70 Hz.
- Output voltage accuracy +/-1%; THDv <2% on linear load.
- Overload: 105% continuous, 125% for 1 min or 130% for 60 s, 150% for 10-30 s.
- Battery voltage 48, 72, 180 and 192 V DC; up to three units in parallel (optional card).
- Runtime: 6 kVA 28.0 min at 25% load, 2.0 min at 100%; 10 kVA 22.3 min at 25%, 1.3 min at 100%.
- Operation 0-40 °C up to 3000 m; derating 1% per 100 m above 1000 m.
- Weight 17.4-63.0 kg; noise below 40 to below 50 dB.
Using it in design
- Compare load in kW (at most 90% of kVA) rather than kVA; for example the 6 kVA model gives 5400 W.
- The tabulated runtimes are for the internal batteries; if longer autonomy is needed, confirm external battery options per model.
- On grids with low supply voltage, account for the transfer to battery at full load below 176 V (or 185 V).
- Apply the 1% per 100 m derating above 1000 m to capacity at high-altitude sites.
- State the three-unit parallel limit and the optional parallel card in the specification when redundancy is needed.
Who should read it
Electrical designers and resellers selecting 2-10 kVA single-phase UPS for small rooms, edge sites and telecom or security applications.
Document contents
- Description
- Features and applications
- Technical specification
- Runtime estimates
- Rear panel
- Product codes
Publication details
- Authors
- Sollatek
- Publisher
- Sollatek
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Sollatek Sollatek Maxima Online 2-10kVA datasheet10911064 Oct2025 v3, pp.2-4. Sollatek. https://www.sollatek.com/wp-content/uploads/2025/02/Maxima-Online-Series-2-to-10kVA-1P-Datasheet-10911064-Oct-2025-v3.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.