Qoltec 53985 official technical data: 3-phase UPS 20kVA / 16kW low frequency
Original title Qoltec 53985 official technical data
Qoltec
The Qoltec 53985 is a 20 kVA / 16 kW three-phase low-frequency (transformer-based) online UPS with 380 V input ± 25 percent, a 384 V DC battery set (32 x 12 V), 0 ms transfer time and 136 kg weight.
On this page
Overview
The page presents Qoltec's three-phase low-frequency online UPS, product code 53985. The unit is rated 20 kVA apparent and 16 kW active power, with a power factor of 0.8 and pure sine output. Input voltage is 380 V AC ± 25 percent and input frequency is 50 Hz ± 10 percent. Output is 380 V AC, given as ± 1 percent at steady load and ± 5 percent under load. Frequency is 50 Hz in mains operation and 50 or 60 Hz ± 0.05 percent in battery operation.
The battery system is not included. The standard configuration is 32 batteries of 12 V, a 384 V DC battery set; 40 batteries giving 480 V DC are optional. Charging current is selected from 1 to 40 A according to battery capacity. Transfer time is 0 ms, crest factor is 3:1 and the unit switches to bypass after 4 ms on overload. Protections cover overload, over voltage, short circuit and high and low voltage.
Communication is provided through RS-485, RS-232, EPO and SNMP; an LCD and a built-in SNMP module are fitted. Noise is between 40 and 50 dB. Recommended applications are server rooms and data centres, network equipment, computers and office equipment, monitoring and industrial automation, production and industrial equipment, and medical systems. Operating temperature is 0 to +40 °C and storage temperature is -15 to +60 °C.
Dimensions are 656 x 404 x 817 mm (D x W x H), net weight 136 kg and gross weight 148 kg. The unit is CE and RoHS certified with a 24-month warranty. The page gives no runtime value.
Key points
- Model 53985; 20 kVA / 16 kW; power factor 0.8; three-phase pure sine; low-frequency online.
- Input 380 V AC ± 25 percent; input frequency 50 Hz ± 10 percent.
- Output 380 V AC ± 1 percent (steady load), ± 5 percent (under load).
- Batteries not included; 32 x 12 V (384 V DC), optional 40 (480 V DC); charging current 1-40 A.
- Transfer time 0 ms; bypass after 4 ms on overload; crest factor 3:1.
- RS-485, RS-232, EPO, SNMP; LCD; built-in SNMP module; noise 40-50 dB.
- 656 x 404 x 817 mm; net 136 kg; gross 148 kg; 0 to +40 °C.
- CE, RoHS; 24-month warranty.
Using it in design
- Compare the 16 kW active power limit with the load's real kW; the power factor is 0.8.
- For the battery set, choose 32 or 40 blocks of 12 V and the string charging current (1-40 A) from the battery manufacturer's data.
- Include the 136 kg weight in floor loading and the handling plan.
- Connect the RS-485 and SNMP interfaces to the building monitoring system.
- Assess the wide input range (± 25 percent) for generator and weak-grid conditions.
Who should read it
Designers selecting 20 kVA class three-phase UPS units for server rooms and small data centres.
Document contents
- Product description
- Technical data
- Other parameters
- Package contents
Publication details
- Authors
- Qoltec
- Publisher
- Qoltec
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Qoltec Qoltec 53985 official technical data. Qoltec. https://www.qoltec.com/product/duplicate-qoltec-uninterruptible-power-supply-ups-3-phase-10kva-8kw-lcd
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.