Technical guideFree to readYear not stated

Qoltec 53983 official technical data: 3-phase UPS 10kVA / 8kW high frequency

Original title Qoltec 53983 official technical data

Qoltec

The Qoltec 53983 is a 10 kVA / 8 kW three-phase high-frequency online UPS with 400 V (3Ph+N) rating, 0 ms transfer time, built-in SNMP module, delivery without batteries and 33 kg weight.

On this page

Overview

The page presents Qoltec's three-phase high-frequency online UPS, product code 53983. The unit is rated 10 kVA apparent and 8 kW active power, provides pure sine output, and its rated voltage is written as 400 V AC (3Ph+N). Three-phase input voltage is 190-520 V AC at 50 percent load and 305-478 V AC at 100 percent load. In battery mode the output is 3 x 380 V AC (3Ph+N) ± 1 percent at 50/60 Hz ± 0.05 Hz.

Transfer time is 0 ms and crest factor is 3:1; on overload the unit switches to bypass within 4 ms. Protections cover over voltage, overload, short circuit, high and low voltage and over temperature. The battery set is 20 blocks of 12 V, giving 240 V DC. Charging time in the standard type is 8 hours to 90 percent of battery capacity. The unit is delivered without batteries; the battery set is built from 12 V blocks.

Communication is provided through USB, RS-232 and a built-in SNMP module; an LCD and an EPO input are also fitted. Noise is below 60 dB. Operating temperature is 0 to +40 °C, storage temperature is -15 to +60 °C and relative humidity is 20-95 percent. The package contains the UPS, USB-B cable, power cable, user manual, SNMP manual, ViewPowerPro software and warranty card.

Dimensions are 570 x 250 x 540 mm (D x W x H), net weight 33 kg and gross weight 36 kg. The unit is CE and RoHS certified with a 24-month warranty. The page gives no runtime value; runtime depends on the battery capacity chosen.

Key points

  1. Model 53983; 10 kVA / 8 kW; three-phase pure sine; high-frequency online.
  2. Rated voltage 400 V AC (3Ph+N); input 190-520 V AC (50 percent load) and 305-478 V AC (100 percent load).
  3. Battery-mode output 3 x 380 V AC ± 1 percent; 50/60 Hz ± 0.05 Hz.
  4. Transfer time 0 ms; bypass within 4 ms on overload; crest factor 3:1.
  5. The battery set is 20 blocks of 12 V, giving 240 V DC.
  6. Standard-type charging time: 8 hours to 90 percent of capacity.
  7. USB, RS-232, built-in SNMP; EPO; LCD; noise below 60 dB.
  8. 570 x 250 x 540 mm; net 33 kg; 0 to +40 °C; CE, RoHS; 24-month warranty.

Using it in design

  • In the distribution design, check the three-phase connection with neutral (3Ph+N) and the load-dependent input voltage range.
  • Select battery capacity for runtime; the unit ships without batteries and the page gives no runtime.
  • Connect the built-in SNMP module to the building monitoring system and add the EPO input to the emergency shutdown circuit.
  • Assess noise (below 60 dB) and weight in the room layout.

Who should read it

Technical-room and small data-centre designers selecting mid-range three-phase UPS units.

Document contents

  1. Product description
  2. Technical data
  3. Other parameters
  4. Package contents

Publication details

Authors
Qoltec
Publisher
Qoltec
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Qoltec Qoltec 53983 official technical data. Qoltec. https://www.qoltec.com/product/qoltec-3-phase-ups-20kva-20kw-lcd-epo-usb-power-factor-10

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.