Technical guideFree to read2026

Shenling Air-Cooled Scroll Modular Chiller catalogue, 20 April 2026

Original title Shenling Air-Cooled Scroll Modular Chiller, 20260420, printed pp.22,24,31,33

Shenling

Shenling's April 2026 modular scroll chiller catalogue arranges R410A E, C, EVI and EVI Pro series by climate zone; the E series spans 130-460 kW with EER 3.20-3.38 at 7 °C water and 35 °C air.

On this page

Overview

The catalogue groups Guangdong Shenling Environmental Systems' modular air-cooled scroll chillers into four series by climate zone: E series (temperate), C series (areas requiring year-round cooling), EVI series (cold climate) and EVI Pro series (extremely cold climate). All use R410A; the catalogue states a maximum EER of 3.45 (EVI series), maximum COP of 3.70 (EVI Pro series) and maximum CSPF of 4.35.

Capacity control on a single unit is four-level at 25-50-75-100%; combining 16 units modularly gives stepless adjustment as precise as 1.5%. AI-learning tiered and optimal startup reduce starting current and run the best performing compressors and units first. A wide capacity range and a 5-55 °C water range are presented.

The E series table (on/off control, 380 V/3N~/50 Hz) lists LSQRF130PST, LSQRF135PSE, LSQRF280PSE, LSQRF345PST and LSQRF460PST at 130, 135, 280, 345 and 460 kW cooling; cooling power 40.6, 39.9, 82.8, 107.8 and 143.7 kW; EER 3.20, 3.38, 3.38, 3.20 and 3.20; heating COP at -15 °C of 3.32 or 3.51. CSPF ranges from 4.1 to 4.35. Noise is 69-79 dB(A), the refrigerant R410A and the throttling device an EXV.

All tables share one condition: 7 °C leaving water, 0.172 m³/(h kW) flow and 35 °C outdoor dry-bulb. Net and gross weights are given separately. The catalogue introduces the product family; data centre critical load conditions (high water temperature, N+1) are not specifically addressed.

Key points

  1. Four series: E (temperate), C (year-round cooling), EVI (cold), EVI Pro (extremely cold); all R410A.
  2. Maximum EER 3.45 (EVI), maximum COP 3.70 (EVI Pro), maximum CSPF 4.35.
  3. Four-level 25-50-75-100% control per unit; stepless to 1.5% with 16 units combined.
  4. E series: 130, 135, 280, 345 and 460 kW; EER 3.20-3.38; heating COP at -15 °C 3.32-3.51.
  5. E series cooling power 39.9 to 143.7 kW; noise 69-79 dB(A).
  6. Water temperature operating range 5-55 °C.
  7. All tables are given at 7 °C leaving water, 0.172 m³/(h kW), 35 °C ambient.
  8. Net and gross weights are listed separately.
  9. Power supply 380 V/3N~/50 Hz.

Using it in design

  • Check how staged capacity control in a modular multi-unit layout matches the data centre load profile; precision to 1.5% with up to 16 units improves part-load efficiency.
  • Correct capacity and EER from 35 °C ambient to the hotter data centre design conditions.
  • Choose the series by climate zone: EVI or EVI Pro in cold climates, E series in temperate ones.
  • Set module count with N+1 logic and add each module's net weight to the roof load.
  • Compare the 5-55 °C water side range with high-temperature chilled water designs.

Who should read it

Mechanical designers selecting modular air-cooled chillers.

Document contents

  1. Company profile
  2. Development history
  3. Core advantage
  4. E Series: for temperate climate zone
  5. C Series: for areas requiring year-round cooling
  6. EVI Series: for cold climate zone
  7. EVI Pro Series: for extremely cold climate zone
  8. Performance cases

Publication details

Authors
Shenling
Publisher
Shenling
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Shenling (2026). Shenling Air-Cooled Scroll Modular Chiller, 20260420, printed pp.22,24,31,33. Shenling. https://img.shenlinghvac.com/attachment/1/file/7063/Shenling%20Air-Cooled%20Scroll%20Modular%20Chiller_Ver.20260420.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.