Rear Door Cooler

Shenling

The Shenling rear door cooler is a manufacturer page for a rack-level cooling product that removes heat through a backplane beside the servers, keeps water out of the room and claims 100% sensible heat ratio.

On this page

Overview

Guangdong Shenling Environmental Systems presents the rear door cooler as a cabinet-level solution for next-generation high-density data centres. Heat is exchanged directly and efficiently through a backplane tightly integrated with the servers, so the cooling loop stays fully isolated from room air.

The headline claim is that this isolated loop reaches a 100% sensible heat ratio (SHR) and removes the risk of water leakage at its root. The page describes all-dry operation with no water in the equipment room, and lists anti-condensation protection and a refrigerant leakage alarm.

The design approach emphasises an integrated build, high compatibility and easy expansion. The page ties the product to ICT data-centre applications and lists dehumidifiers, constant-humidity units, humidifiers and a data-centre fresh-air unit with temperature and humidity management as related products. It gives no model capacity, ordering table or measured performance values.

Key points

  1. Cabinet-level rear door cooling aimed at next-generation high-density data centres.
  2. Heat leaves through a backplane next to the servers; the cooling loop is isolated from room air.
  3. A 100% sensible heat ratio (SHR) and removal of water-leak risk are the manufacturer's main claims.
  4. All-dry operation: no water in the equipment room.
  5. Integrated design, high compatibility and easy expansion.
  6. Anti-condensation protection and a refrigerant leakage alarm are listed features.
  7. No numeric ratings (kW, flow, pressure drop) are given on the page.

Using it in design

  • For white space that cannot accept water, compare this dry refrigerant-based rear door with chilled-water rear doors; do not assume a chilled-water terminal from this page.
  • Match heat load per cabinet to the manufacturer's capacity table; the page has no model capacities, so request selection data from the supplier.
  • Wire the refrigerant leakage alarm into the building management system (BMS) alarm list and the response procedure.
  • Check the anti-condensation feature against design wet-bulb and dew-point conditions.

Who should read it

Data-centre designers weighing cooling options for high-density racks where water must stay out of the room.

Document contents

  1. Rear Door Cooler
  2. Applications: ICT Data Center
  3. Related products
  4. Product enquiry

Publication details

Authors
Shenling
Publisher
Shenling
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Shenling Rear Door Cooler. Shenling. https://www.shenling.com/en/products/rear-panel-precision-air-conditioner/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.