Rear Door Cooler
Shenling
The Shenling rear door cooler is a manufacturer page for a rack-level cooling product that removes heat through a backplane beside the servers, keeps water out of the room and claims 100% sensible heat ratio.
On this page
Overview
Guangdong Shenling Environmental Systems presents the rear door cooler as a cabinet-level solution for next-generation high-density data centres. Heat is exchanged directly and efficiently through a backplane tightly integrated with the servers, so the cooling loop stays fully isolated from room air.
The headline claim is that this isolated loop reaches a 100% sensible heat ratio (SHR) and removes the risk of water leakage at its root. The page describes all-dry operation with no water in the equipment room, and lists anti-condensation protection and a refrigerant leakage alarm.
The design approach emphasises an integrated build, high compatibility and easy expansion. The page ties the product to ICT data-centre applications and lists dehumidifiers, constant-humidity units, humidifiers and a data-centre fresh-air unit with temperature and humidity management as related products. It gives no model capacity, ordering table or measured performance values.
Key points
- Cabinet-level rear door cooling aimed at next-generation high-density data centres.
- Heat leaves through a backplane next to the servers; the cooling loop is isolated from room air.
- A 100% sensible heat ratio (SHR) and removal of water-leak risk are the manufacturer's main claims.
- All-dry operation: no water in the equipment room.
- Integrated design, high compatibility and easy expansion.
- Anti-condensation protection and a refrigerant leakage alarm are listed features.
- No numeric ratings (kW, flow, pressure drop) are given on the page.
Using it in design
- For white space that cannot accept water, compare this dry refrigerant-based rear door with chilled-water rear doors; do not assume a chilled-water terminal from this page.
- Match heat load per cabinet to the manufacturer's capacity table; the page has no model capacities, so request selection data from the supplier.
- Wire the refrigerant leakage alarm into the building management system (BMS) alarm list and the response procedure.
- Check the anti-condensation feature against design wet-bulb and dew-point conditions.
Who should read it
Data-centre designers weighing cooling options for high-density racks where water must stay out of the room.
Document contents
- Rear Door Cooler
- Applications: ICT Data Center
- Related products
- Product enquiry
Publication details
- Authors
- Shenling
- Publisher
- Shenling
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Shenling Rear Door Cooler. Shenling. https://www.shenling.com/en/products/rear-panel-precision-air-conditioner/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.