SOETECK DX Packaged In-Row Cooling System model table
Original title SOETECK DX Packaged In-Row Cooling System
SOETECK
SOETECK's DX packaged in-row unit is 300 mm wide with an integrated condenser and inverter compressor; three models (S005PA, S007PA, S010PA) give 5.6, 7.6 and 10.8 kW.
On this page
Overview
The page presents SOETECK's fully self-contained DX packaged in-row system, designed for data centres with limited space for outdoor condensers. It includes an inverter compressor, EC fans and an integrated condenser with adjustable fan speed; the refrigerant is R410A. Target applications are edge computing and modular data centres.
Options include SNMP monitoring, a condensate pump and air-duct connections. Only the 300 mm width is offered, which saves floor space. At low heat loads, inverter modulation reduces compressor wear.
The model table has three models. S005PA: 5.6 kW, 2,000 m³/h, 210 kg. S007PA: 7.6 kW, 2,250 m³/h, 213 kg. S010PA: 10.8 kW, 2,500 m³/h, 233 kg. Sensible capacity equals total capacity in all three; dimensions are 300 mm wide, 1,200 mm deep and 2,000 mm high.
The page title summarises 5.6/7.6 kW total capacity and 2,000/2,250 m³/h airflow. The technical specification and brochure sections are marked as coming soon, and the ambient condition for capacity is not stated.
Key points
- Three models: S005PA 5.6 kW; S007PA 7.6 kW; S010PA 10.8 kW (SHR 100 %).
- Air flow 2,000 / 2,250 / 2,500 m³/h.
- Dimensions 300 x 1,200 x 2,000 mm (W x D x H); weight 210 / 213 / 233 kg.
- Integrated condenser with adjustable-speed EC fan; no outdoor unit needed.
- Inverter compressor and R410A.
- Options: SNMP monitoring, condensate pump, air-duct connection.
Using it in design
- In edge and micro data centres with no room for an outdoor condenser, check that integrated heat rejection suits the space; plan the condenser air discharge and hot-air recirculation.
- The ambient condition for capacity is not stated, so obtain capacity confirmation for indoor and outdoor temperatures before ordering.
- Show condensate drainage and optional air-duct connections on the mechanical plan.
- Consider it a single-row solution for loads of 10.8 kW and below; move to a DX split series for larger loads.
Who should read it
Mechanical engineers designing edge and micro data-centre cooling.
Document contents
- Overview
- Key features
- Model range
- Models table
- Technical specifications (to be published)
Publication details
- Authors
- SOETECK
- Publisher
- SOETECK
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
SOETECK SOETECK DX Packaged In-Row Cooling System. SOETECK. https://soeteck.com/en/products/thermal-management/precision-air-conditioning/soeteck-dx-packaged-in-row-cooling-system-5-6kw-10-8kw-capacity/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.