ECO SNM Monobloc Centrifugal Pumps: Operation and Maintenance Manual

Original title ECO SNM Monoblok Santrifüj Pompalar: İşletme ve Bakım Kılavuzu

Standart Pompa

Standart Pompa's August 2016 Turkish operation and maintenance manual for ECO SNM monobloc centrifugal pumps: DN32-DN150, -10 to +140 °C, up to 10 bar (16 bar), pipe velocity limits 2 and 3 m/s.

On this page

Overview

The document is the Turkish operation and maintenance manual for Standart Pompa's ECO SNM monobloc centrifugal pumps (08.2016, revision 0). After safety provisions, temperature classes, pump description and nameplate information come sections on unpacking, handling and storage, installation, start-up, disassembly and fault finding.

According to the technical data, the discharge flange is DN32-DN150, operating temperature -10 to +140 °C and casing pressure up to 10 bar (16 bar optional). In temperature class T4 the maximum surface temperature is 135 °C and maximum fluid temperature 110 °C; in T3 they are 200 and 180 °C. The pumps are for low-viscosity, clean or slightly contaminated liquids.

The installation section limits pipe velocity to 2 m/s on suction and 3 m/s on delivery, because high velocity causes pressure drop and cavitation. The suction pipe should be short, tight and sloped so as not to form air pockets. For star/delta starting, the changeover time must be very short; the Y setting time is under 3 seconds for motors up to 30 kW. A minimum-flow provision protects against long operation on a closed valve.

The manual covers a general pump family; it holds no data-centre content or project duty. Its value is as a source for a site checklist on installation, first start and maintenance of chilled-water pumps.

Key points

  1. Discharge flange DN32-DN150; casing pressure up to 10 bar, 16 bar optional.
  2. Operating temperature -10 to +140 °C; temperature class T4 allows maximum fluid 110 °C, T3 allows 180 °C.
  3. Pipe velocity must not exceed 2 m/s on the suction pipe and 3 m/s on the delivery pipe.
  4. The suction pipe should be as short as possible, tight and sloped to avoid air pockets.
  5. At start-up the delivery valve is closed and suction valve open; the pump and suction pipe must be filled with water.
  6. For star/delta starting the changeover time must be very short; the Y setting time is under 3 seconds for motors up to 30 kW.
  7. For minimum flow, a by-pass valve is provided where operation near a closed valve is possible.
  8. The manual also has tables for spare parts, fault causes and estimated noise levels.

Using it in design

  • In a chilled-water pump specification, write the pipe velocity limits (suction 2 m/s, delivery 3 m/s) and a short suction line as design criteria.
  • Set suction pipe slope for flooded-suction and suction-lift installations from the figures and prevent air pockets.
  • Add the star/delta changeover-time setting to commissioning tests for motors started that way.
  • Provide a by-pass or automatic speed-controlled logic for minimum-flow protection.
  • Compare the pump temperature and pressure limits (140 °C, 10 bar) with the operating conditions of the cooling circuit.

Who should read it

Site engineers and operations teams who install, commission and maintain chilled-water pumps.

Document contents

  1. General and Safety
  2. General Pump Description
  3. Unpacking, Handling and Storage
  4. Installation on Site
  5. Start-up and Shut-down
  6. Disassembly and Assembly
  7. Spare Parts
  8. Faults, Causes and Remedies
  9. Estimated Noise Levels

Publication details

Authors
Standart Pompa
Publisher
Standart Pompa
Year
2016
Document number
08.2016, Revizyon 0
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Public source opened on the access date. No open redistribution licence established; metadata and original short summaries only. Copyright notice on PDF p.2 forbids reproduction without written permission.

Citation

Standart Pompa (2016). ECO SNM Monoblok Santrifüj Pompalar: İşletme ve Bakım Kılavuzu. Standart Pompa. 08.2016, Revizyon 0. https://www.standartpompa.com/tr/images/pdf/bakimkilavuzu/ecosnm-(tur)-bakim%20kilavuzu.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.