Technical guideFree to readYear not stated

SWEP Solutions: Exceptional performance in Data Center Cooling

SWEP

SWEP's application brochure shows brazed plate heat exchangers in CDU, mechanical cooling, free-cooling, immersion and heat-recovery circuits; in free-cooling an exchanger separates the external glycol circuit from the server circuit.

On this page

Overview

The SWEP brochure uses application diagrams to show where brazed plate heat exchangers are used in data-centre cooling. The circuits covered are CDU (coolant distribution unit), mechanical cooling, free-cooling, immersion cooling and heat recovery.

In the free-cooling arrangement a heat exchanger separates the external glycol circuit from the internal circuit serving the servers, so the glycol stays outdoors and the internal circuit stays glycol-free. In immersion cooling applications, double-wall heat exchangers are described as a way to detect internal leakage and limit fluid mixing.

Key points

  1. Shows brazed plate heat exchangers in CDU, mechanical cooling, free-cooling, immersion and heat-recovery circuits.
  2. In free-cooling, the exchanger separates the external glycol circuit from the server circuit.
  3. In immersion applications, double-wall exchangers detect internal leakage and limit fluid mixing.
  4. The heat-recovery circuit appears as an exchanger application for passing data-centre heat to another use.

Using it in design

  • In a free-cooling circuit, place an exchanger between outdoor glycol and the internal water circuit to reject heat without bringing glycol inside; set the exchanger approach temperature against free-cooling hours.
  • In CDU design, separate primary and secondary circuits with an exchanger and manage the pressure and fluid quality difference there.
  • In immersion cooling, use a double-wall exchanger to reduce leakage risk.
  • For heat recovery, define the heat delivery temperature and the receiving circuit at the outset.

Who should read it

Mechanical engineers designing data-centre cooling circuits and heat recovery.

Publication details

Authors
SWEP
Publisher
SWEP
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.

Citation

SWEP SWEP Solutions: Exceptional performance in Data Center Cooling. SWEP. https://www.swepgroup.com/content/dam/swep/data-center/brochures/Data%20center%20brochure%20EN.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.