TS EN 50600-4-6: Energy reuse factor
Türk Standardları Enstitüsü (TSE), 2020, Standard
TS EN 50600-4-6 is part of the EN 50600 series and covers the energy reuse factor (ERF); it is the Turkish adoption of EN 50600-4-6:2020.
Standard
2020
Topic
73–96 / 725
Türk Standardları Enstitüsü (TSE), 2020, Standard
TS EN 50600-4-6 is part of the EN 50600 series and covers the energy reuse factor (ERF); it is the Turkish adoption of EN 50600-4-6:2020.
Standard
2020
Türk Standardları Enstitüsü (TSE), 2020, Standard
TS EN 50600-4-7 is part of the EN 50600 series and covers the cooling efficiency ratio (CER); it is the Turkish adoption of EN 50600-4-7:2020.
Standard
2020
Türk Standardları Enstitüsü (TSE), 2023, Standard
TS EN 50600-4-8 is part of the EN 50600 series and covers carbon usage effectiveness (CUE); it is the Turkish adoption of EN 50600-4-8:2022.
Standard
2023
Türk Standardları Enstitüsü (TSE), 2023, Standard
TS EN 50600-4-9 is part of the EN 50600 series and covers water usage effectiveness (WUE); it is the Turkish adoption of EN 50600-4-9:2022.
Standard
2023
Türk Standardları Enstitüsü (TSE), 2025, Standard
TSE CLC/TS 50600-4-31 is part of the EN 50600 series and covers key performance indicators for resilience; it is the Turkish adoption of CLC/TS 50600-4-31:2024.
Standard
2025
Türk Standardları Enstitüsü (TSE), 2023, Standard
TSE CLC/TS 50600-5-1 is part of the EN 50600 series and covers the maturity model for energy management and environmental sustainability; it is the Turkish adoption of CLC/TS 50600-5-1:2023.
Standard
2023
European Commission, Joint Research Centre, 2024, Regulation
The European Commission JRC guidance JRC136986, dated 27 February 2024, is the annual best-practice revision for participants in the EU Code of Conduct on Data Centre Energy Efficiency.
Regulation
2024
Enerji Piyasası Düzenleme Kurumu, 2026, Regulation
EPDK report on Turkey's 2025 electricity data: total installed capacity 123,167.98 MW, generation 354,584.16 GWh, renewable share of capacity 62.33%, weighted average market clearing price 2,651.81…
Regulation
2026
Türkiye Büyük Millet Meclisi, 2025, Regulation
Turkey's first framework climate law. It sets the net-zero/green-growth goal, creates a national Emissions Trading System (ETS) run by the Climate Change Presidency, makes a greenhouse-gas emission…
Regulation
2025
European Commission, Joint Research Centre, 2023, Regulation
JRC describes this framework as a bridge between Code of Conduct practices and audit evidence for Taxonomy activity 8.1. It is intended to support checks of whether the practices have been applied.…
Regulation
2023
Enerji Piyasası Düzenleme Kurumu, 2026, Regulation
EPDK amending regulation of 19.10.2026 (Official Gazette 33405): a new document for distribution-connected sites in demand-side participation, 10% and 25% monitoring thresholds, capacity fee reductio…
Regulation
2026
Enerji Piyasası Düzenleme Kurumu (EPDK), 2020, Regulation
Creates Turkey's renewable energy guarantee-of-origin system (YEK-G). One electronic certificate is issued per MWh of renewable generation, certificates are valid for 12 months after the production…
Regulation
2020
T.C. Enerji ve Tabii Kaynaklar Bakanlığı, 2020, Regulation
Ministry of Energy regulation on acceptance (kabul) of electricity generation and storage facilities and their operating-period obligations.
Regulation
2020
European Commission, Joint Research Centre, 2023, Regulation
The European Commission JRC introductory guide v3.4.0 of 15 February 2023 (JRC124057) is the application guide for organisations wishing to join the EU data-centre Code of Conduct.
Regulation
2023
T.C. Enerji ve Tabii Kaynaklar Bakanlığı – Enerji Verimliliği ve Çevre Dairesi (EVÇED), 2026, Regulation
Ministry of Energy progress report on Turkey's second National Energy Efficiency Action Plan (2024-2030).
Regulation
2026
European Parliament and Council of the European Union, 2024, Regulation
Framework legislation for sustainable-product ecodesign and digital product passports.
Regulation
2024
T.C. Çevre ve Şehircilik Bakanlığı (bugün Çevre, Şehircilik ve İklim Değişikliği Bakanlığı), 2014, Regulation
Turkey's GHG monitoring, reporting and verification (MRV) regulation for installations listed in Annex 1.
Regulation
2014
T.C. Enerji ve Tabii Kaynaklar Bakanlığı – Enerji Verimliliği ve Çevre Dairesi (EVÇED), 2024, Regulation
Official Turkish electricity emission factors from the Ministry of Energy for 2022: national generation average, per-fuel generation factors and consumption-point factors for transmission- and distri…
Regulation
2024
Enerji Piyasası Düzenleme Kurumu, 2026, Regulation
The Energy Market Regulatory Authority's regulation of 21 October 2026 (Official Gazette 33407) governs how the Turkish Emissions Trading System market and registry system operate.
Regulation
2026
Çevre, Şehircilik ve İklim Değişikliği Bakanlığı, 2026, Regulation
The environment ministry's regulation of 27 August 2026 (Official Gazette 33353) combines MRV duties for Annex 1 activities with Turkish ETS implementation; records must be kept for at least ten year…
Regulation
2026
T.C. Enerji ve Tabii Kaynaklar Bakanlığı – Enerji Verimliliği ve Çevre Dairesi (EVÇED), 2024, Regulation
Official Turkish grid emission factors for project-based reduction calculations (UNFCCC CDM Tool 07), giving operating margin, build margin and combined margin values for 2021.
Regulation
2024
European Commission JRC, 2017, Regulation
The EU Code of Conduct best practice catalogue valid for 2017 (version 8.1.0). Practices are tagged by when they are expected (existing site, new IT, new software, new build or retrofit) and by value…
Regulation
2017
European Commission JRC, 2018, Regulation
The EU Code of Conduct best practice catalogue for 2018 (version 9.1.0). It keeps the 2017 structure, clarifies free cooling and air flow practices, and plans to make air quality monitoring a minimum…
Regulation
2018
Türkiye Büyük Millet Meclisi, 2007, Regulation
Law No. 5627 is the Turkish framework law on energy efficiency; it obliges energy-management roles in industry and large buildings, enables state support for efficiency projects and allows energy…
Regulation
2007