RegulationPDF2007

Law No. 5627 on Energy Efficiency (5627 sayılı Enerji Verimliliği Kanunu)

Original title 5627 sayılı Enerji Verimliliği Kanunu

Türkiye Büyük Millet Meclisi

Law No. 5627 is the Turkish framework law on energy efficiency; it obliges energy-management roles in industry and large buildings, enables state support for efficiency projects and allows energy performance contracts in the public sector.

Copyright retained; citation only: the publisher’s terms apply to the original document

On this page

Overview

Law No. 5627 on Energy Efficiency was published in the Official Gazette no. 26510 on 2 May 2007. Its stated purposes are the efficient use of energy, avoiding waste, easing the burden of energy costs on the economy and protecting the environment (Article 1). It is a framework law, with detailed procedures set by regulations. This record is based on the consolidated text on mevzuat.gov.tr as of November 2026. The provisions most relevant to data center design are in Article 7.

Commercial, service and public buildings with a floor area of at least 20 000 m2 or annual energy consumption of 500 TEP or more must appoint or contract an energy manager. Non-public industrial enterprises consuming 50 000 TEP per year or more must set up an energy management unit. The law also regulates support and contracting mechanisms. Efficiency projects can be supported up to 30% of cost, capped at 15 million TL and revalued annually (Article 8(1)(a), as amended in 2024).

Public bodies may sign energy performance contracts of up to 15 years (Additional Article 1). Large data-centre buildings typically exceed the floor-area or energy thresholds and therefore fall under the energy-manager obligation. For detail not covered in this record, the related regulations apply: the Regulation on Increasing Efficiency in the Use of Energy Resources and Energy, and the Regulation on Energy Performance in Buildings. ISO 50001 is a related management system standard.

Key points

  1. Purpose: efficient use of energy, avoiding waste, easing the burden of energy costs and protecting the environment (Article 1).
  2. Commercial, service and public buildings with at least 20 000 m2 or annual consumption of 500 TEP or more must appoint or contract an energy manager (Article 7(1)(a)(2)).
  3. Non-public industrial enterprises consuming 50 000 TEP/year or more must set up an energy management unit (Article 7(1)(a)(3)).
  4. Efficiency projects can be supported up to 30% of cost, capped at 15 million TL (revalued annually) (Article 8(1)(a), amended 2024).
  5. Public bodies may sign energy performance contracts of up to 15 years (Additional Article 1).
  6. Large data-centre buildings typically exceed the floor-area or energy thresholds.
  7. Related instruments: the related regulations and ISO 50001.

Using it in design

  • Convert annual facility energy from the energy model into tonnes of oil equivalent (TEP).
  • Flag when the site crosses the 500 TEP / 20 000 m2 thresholds so the owner can plan an energy manager and reporting.
  • Reuse PUE and energy outputs for those reports.
  • For public-sector clients, consider the energy performance contract option in the investment model.
  • Verify current values from the legislation, since support terms and caps change annually.

Who should read it

Data center owners, operators and engineers in Turkey responsible for energy efficiency and regulatory compliance.

Related standards

  • Enerji Kaynaklarının ve Enerjinin Kullanımında Verimliliğin Artırılmasına Dair Yönetmelik
  • Binalarda Enerji Performansı Yönetmeliği
  • ISO 50001

Read the document

tr-5627-enerji-verimliligi-kanunu.pdf

PDF · 0.2 MB · Turkish

Copyright retained; citation only: the publisher’s terms apply to the original document

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
Türkiye Büyük Millet Meclisi
Publisher
Türkiye Büyük Millet Meclisi
Year
2007
Document number
Kanun No. 5627 (RG 26510, 02.05.2007)
Document language
Turkish
Source type
Turkish regulation
Access
Open licence (downloadable)
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Licence evidence
www.mevzuat.gov.tr
Original licence note

Official Turkish legislation published in the Resmî Gazete; FSEK (Law 5846) Art. 31 allows laws and regulations to be reproduced freely.

Citation

Türkiye Büyük Millet Meclisi (2007). 5627 sayılı Enerji Verimliliği Kanunu. Türkiye Büyük Millet Meclisi. Kanun No. 5627 (RG 26510, 02.05.2007). https://www.mevzuat.gov.tr/MevzuatMetin/1.5.5627.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.