Institutional SOME (CSIRT) Establishment and Management Guide
Original title Kurumsal SOME Kurulum ve Yönetim Rehberi
Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü
A July 2014 guide from Turkey's Ministry of Transport, Maritime Affairs and Communications on setting up and running an institutional cyber incident response team (Kurumsal SOME) in public bodies and critical-infrastructure operators.
On this page
Overview
The guide was prepared for organisations obliged to form an institutional response team under the regulation on the establishment, duties and work of cyber incident response teams, published in the Official Gazette on 11 November 2013. Scope covers all public bodies with a standalone IT unit and private operators of critical infrastructure, and the same provisions apply where IT services are bought from contractors. Organisations may apply the content in proportion to their size and capability.
The structure has three tiers: USOM provides national technical support and coordination, sectoral teams handle regulation and coordination at sector level, and institutional teams respond to incidents inside their own organisation. The team may sit inside or outside the IT department, ideally under a manager whose main responsibility is cyber security. Five functions are defined: unit management, incident response management and coordination, system testing and auditing, security awareness, and log analysis.
Duties are split by time. Before an incident: awareness activities, penetration tests and central log management, with log administration kept independent of the owners of the systems that generate the logs, as a segregation-of-duties measure. During an incident: a flow diagram covering assessment, coordination with IT, contact with the internet service provider, sectoral team and USOM as needed, and notification of prosecutors or police when a crime is suspected. After an incident: identify the vulnerability, record lessons, and produce a response report.
The document dates from 2014 and reflects the institutional responsibilities of that time; provisions such as the September 2014 establishment deadline are historical context. Process elements such as log management, notification forms, contact-information sharing and post-incident learning remain a useful template for teams writing incident procedures for data-centre operations. Annexes contain a contact form, incident notification and evaluation forms, and the establishment requirements list.
Key points
- Scope: public bodies with a standalone IT unit and private critical-infrastructure operators, including those that outsource IT.
- Five functions for an institutional team: unit management, incident response management and coordination, system testing and auditing, awareness, log analysis.
- Staffing guidance: associate or bachelor degree and at least two years of IT experience (or security experience); team lead with at least a bachelor degree and security specialisation.
- Contracted staff require a security background check and a non-disclosure agreement.
- Logs are kept centrally, reviewed daily and analysed periodically (weekly, monthly); administration is independent of the owners of the logging systems.
- Logging beyond the minimum list is recommended from user terminals, honeypots, data-loss-prevention and URL-filtering systems.
- Post-incident: identify the exploited weakness quickly, record lessons, report via the Annex 3 form to USOM and the sectoral team, propose corrective actions and write a detailed response report.
- Incident types, counts and costs are tracked; 24/7 contact details are submitted to USOM on a standard form.
Using it in design
- Adopt the before/during/after structure and the post-incident report template in the data centre's incident management procedure.
- Route BMS, SCADA and DCIM logs to a central log store administered independently of the system owners, and make that segregation a design requirement.
- Add a 24/7 contact form listing the on-call team, internet service provider and security appliance inventory to the operations file.
- If the facility is critical infrastructure, confirm the current sectoral and national reporting channels instead of relying on the 2014 responsibilities in this guide.
- Put penetration testing and awareness activities on a scheduled calendar with a named owner in the operations plan.
Who should read it
Managers and engineers in public bodies or critical infrastructure who own information security, incident response and data-centre operations procedures.
Document contents
- Executive summary
- Introduction: purpose, scope, definitions, basis, related legislation, updating, confidentiality
- National cyber incident response organisation
- Establishing an institutional SOME: place in the organisation and capacity planning, internal stakeholders, external stakeholders, training, establishment timeline and principles
- Duties and responsibilities: before, during and after a cyber incident
- Annexes: contact form, incident notification form, incident evaluation form, requirements list
Publication details
- Authors
- Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü
- Publisher
- Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü
- Year
- 2014
- Document number
- Sürüm 1 / Temmuz 2014
- Document language
- Turkish
- Source type
- Government / public
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Açık erişim yeniden dağıtım izni anlamına gelmez; açık yeniden dağıtım lisansı saptanmadı. Kütüphanede tam metin yayımlanmaz. USOM resmi PDF arşivi; tarihsel sürüm. Güncel mevzuat ve kurum görevleri bu kayıt kapsamında doğrulanmadı.
Citation
Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü (2014). Kurumsal SOME Kurulum ve Yönetim Rehberi. Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü. Sürüm 1 / Temmuz 2014. https://dsy.usom.gov.tr/usom/19/02/190211090329_Kurumsal%20_SOME_Rehberi.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
