Technical guideFree to read2014

Sectoral SOME (CSIRT) Establishment and Management Guide

Original title Sektörel SOME Kurulum ve Yönetim Rehberi

Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü

A November 2014 Turkish guide defining how sectoral cyber incident response teams are set up in the energy, communications, finance, water, transport and critical public service sectors, and how they coordinate with USOM and institutional teams.

On this page

Overview

The guide was written for the regulators of the sectors the Cyber Security Council named as critical under the National Cyber Security Strategy and 2013-2014 Action Plan: transport, energy, electronic communications, finance, water management and critical public services. The hierarchy is that institutional teams respond to incidents inside their own organisation, sectoral teams carry out administrative regulation and coordination across the sector, and USOM provides national technical support and coordination.

The body in which each sectoral team is set up is named: EPDK for energy, BTK for electronic communications, SPK and BDDK for finance, and the Ministry of Forestry and Water Affairs for water management; annexes list the bodies for transport and critical public services. The guide also proposes sector-specific parameters for identifying critical systems: energy produced or transmitted, data carried, deposit volume, water processed, and freight or passenger numbers.

Pre-incident duties cover regulatory work (criteria and thresholds for critical systems, sector legislation, minimum security criteria, framework contract clauses, risk-analysis method, incident procedure and exercises), communication, information sharing and technical measures. The identification of critical systems is repeated at least every two years. Bringing SCADA vendors together with institutional teams and auditing log mechanisms are also listed duties.

During an incident the sectoral team may place an observer, informs its institutional teams and USOM, and ensures that suspected crimes are reported to the authorities. Incidents are grouped in three classes by the need for law-enforcement cooperation: purely internal technical events, attacks, and crimes where evidence sits in computer systems. The guide dates from 2014, so its institutional responsibilities are best read as historical context rather than current governance.

Key points

  1. Sectoral team hosts: EPDK (energy), BTK (electronic communications), SPK and BDDK (finance), Ministry of Forestry and Water Affairs (water).
  2. Critical sectors: transport, energy, electronic communications, finance, water management and critical public services.
  3. Example parameters for critical systems: energy volume, data carried, deposit volume, water volume, freight or passenger numbers; thresholds are set by the sector.
  4. The critical-system identification exercise is repeated at least every two years.
  5. Sectoral and institutional teams share contact details of staff reachable 24/7 with USOM.
  6. The sectoral team coordinates between institutional teams and the vendors of sector-specific SCADA systems, and with communications providers.
  7. Information duties: bulletins, general attack warnings and vulnerability announcements, passing USOM notices to the sector.
  8. Incidents fall into three classes by law-enforcement relevance; suspected crimes are reported without delay and the incident report goes to USOM.

Using it in design

  • For a facility that may count as critical infrastructure, check early whether it falls under your sector's critical-system parameters.
  • Add the external notification chain (sectoral team, national centre, prosecutors, police) and a 24/7 contact list to the incident procedure.
  • Assign an owner to track vendor vulnerability notices for SCADA, BMS and power-monitoring systems.
  • Include information-security clauses from framework contract provisions in procurement specifications.
  • Compare the 2014 institutional responsibilities with current regulation before applying them.

Who should read it

Managers at critical-sector regulators and operators responsible for cyber incident coordination, and engineers drafting infrastructure security policy.

Document contents

  1. Executive summary
  2. Introduction: purpose, scope, definitions, basis, related legislation, updating, confidentiality
  3. National cyber incident response organisation: critical infrastructures and sectoral SOMEs
  4. Establishing a sectoral SOME: capacity planning, internal and external stakeholders, timeline and principles, training
  5. Duties and responsibilities: before an incident (regulation, communication, information, technical measures), during, after
  6. Annexes: contact form, training content, list of host bodies, framework contract clauses

Publication details

Authors
Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü
Publisher
Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü
Year
2014
Document number
Sürüm 1 / Kasım 2014
Document language
Turkish
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Açık erişim yeniden dağıtım izni anlamına gelmez; açık yeniden dağıtım lisansı saptanmadı. Kütüphanede tam metin yayımlanmaz. USOM resmi PDF arşivi; tarihsel sürüm. Kurum/kurul adları 2014 belgesine aittir, güncel yetki iddiası değildir.

Citation

Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü (2014). Sektörel SOME Kurulum ve Yönetim Rehberi. Ulaştırma, Denizcilik ve Haberleşme Bakanlığı / Haberleşme Genel Müdürlüğü. Sürüm 1 / Kasım 2014. https://dsy.usom.gov.tr/usom/19/02/190211090404_Sektorel%20SOME%20Rehberi.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.