Research paperFree to read2025

Advances in Early Warning of Thermal Runaway in Lithium-Ion Battery Energy Storage Systems

Original title Advances in Early Warning of Thermal Runaway in Lithium‐Ion Battery Energy Storage Systems

Advanced Sensor Research (Wiley) · Duzhao Han, Juan Wang et al.

A 2025 Advanced Sensor Research review of sensing technologies and intelligent warning algorithms for early detection of thermal runaway in lithium-ion BESS: temperature, gas, pressure, strain and acoustic signals.

On this page

Overview

The review treats thermal runaway as a critical safety concern in lithium-ion battery energy storage systems and analyses state-of-the-art sensing technologies and strategies for early detection and warning. It discusses the primary inducing factors, the evolution mechanism and characteristic reactions at various stages. Detectable signals during thermal runaway (temperature, gas emissions, pressure, strain and acoustic signals) are examined together with advances in the corresponding sensing technologies.

It highlights the importance of sensor implantation, collaboration and communication within battery cells, and the development of intelligent algorithms and early warning models. Miniaturised, integrated and arrayed sensors within battery cells are identified as an inevitable trend in safety monitoring. Intrinsically safe design considering the distinct thermal runaway characteristics of emerging technologies is also important. Future research should focus on advanced sensing for real-time in situ monitoring, a new paradigm for diagnosis using intelligent algorithms, and integrating battery models with those algorithms.

Key points

  1. Detectable thermal runaway signals: temperature, gas emissions, pressure, strain and acoustic signals.
  2. The review covers inducing factors, evolution mechanism and stage-specific reactions.
  3. Miniaturised, integrated and arrayed in-cell sensors are seen as an inevitable trend.
  4. Combining battery models with intelligent algorithms is recommended for early warning.
  5. Future research should focus on real-time in situ monitoring and a new diagnosis paradigm.

Using it in design

  • In battery room monitoring, consider gas, pressure and where possible acoustic or strain signals, not only temperature, as early warning layers.
  • Plan an early warning architecture that integrates battery management system data with fire detection and is supported by intelligent algorithms.
  • Treat products with in-cell sensors as a feature in supplier selection.
  • For emerging battery technologies, include their thermal runaway characteristics in detection design.

Who should read it

Designers of battery energy storage and data-centre battery monitoring and fire detection, and researchers.

Publication details

Authors
Duzhao Han; Juan Wang; Chengxian Yin; Yuxin Zhao
Publisher
Advanced Sensor Research (Wiley)
Year
2025
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Publisher-deposited Crossref licence metadata: http://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Duzhao Han; Juan Wang; Chengxian Yin; Yuxin Zhao (2025). Advances in Early Warning of Thermal Runaway in Lithium‐Ion Battery Energy Storage Systems. Advanced Sensor Research (Wiley). https://doi.org/10.1002/adsr.202400165

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.