ASHRAE Datacom Series (TC 9.9) - series overview incl. IT Equipment Power Trends 3rd ed., Best Practices for Datacom Facility Energy Efficiency 2nd ed., Particulate and Gaseous Contamination 2nd ed., Green Tips
ASHRAE · ASHRAE TC 9.9
An introduction to the 14-book ASHRAE TC 9.9 Datacom Series, summarising four books (Books 2, 6, 8, 10) that have no record of their own, and what each is used for.
On this page
Overview
This record is based on the ASHRAE bookstore page for the 14-book Datacom Series. The series is produced by ASHRAE TC 9.9 and covers data center cooling, energy, metrics and racks. Because the page blocks automated access, the content rests on catalogue and Handbook descriptions; the books themselves were not read. Four books without their own record here are covered: IT Equipment Power Trends 3rd ed. (Book 2, 2018, product 90454; power trends to 2025 for servers, storage and communication equipment), Best Practices for Datacom Facility Energy Efficiency 2nd ed. (Book 6, 2009, product 90447), Particulate and Gaseous Contamination in Datacom Environments 2nd ed. (Book 8, 2014, product 90568) and Green Tips for Data Centers (Book 10, 2011, product 90554).
The Handbook's description of Book 6 notes that datacom facilities can use about 100 times the energy of an office building and about 3 times the annual operating hours. That ratio summarises why data center energy efficiency is a specialist field of its own. The series content is said to be migrating to the TC 9.9 Datacom Encyclopedia.
This record is therefore a roadmap to which book covers which subject, not a summary of the books' contents. For each subject, the practical step is to obtain the relevant edition and read it directly, using the product number to identify it. In practice, this means checking the product number and edition year before ordering, since several books in the series are older than the current edition of the Thermal Guidelines.
Key points
- The Datacom Series has 14 books; content is migrating to the TC 9.9 Datacom Encyclopedia.
- Book 2: IT Equipment Power Trends, 3rd ed. (2018), product 90454; power trends to 2025 for servers, storage and communication equipment.
- Book 6: Best Practices for Datacom Facility Energy Efficiency, 2nd ed. (2009), product 90447.
- Book 8: Particulate and Gaseous Contamination in Datacom Environments, 2nd ed. (2014), product 90568.
- Book 10: Green Tips for Data Centers (2011), product 90554.
- Datacom facilities can use about 100 times the energy of an office building and about 3 times the annual operating hours.
Using it in design
- Use Book 2 (IT Equipment Power Trends) for default kW-per-rack growth projections.
- Use Book 8 for contamination checks.
- Use Books 6 and 10 for energy-saving checklists.
- Cite the product numbers in references so that the correct edition is identified.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Check cooling capacity alongside your design
Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.
Request a demo
Who should read it
Data center designers looking for which ASHRAE book to consult on cooling and energy efficiency.
Publication details
- Authors
- ASHRAE TC 9.9
- Publisher
- ASHRAE
- Year
- 2024
- Document number
- Datacom Series Books 2, 6, 8, 10
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Copyrighted ASHRAE book sold via ASHRAE Bookstore (and TC 9.9 Datacom Encyclopedia subscription). Not read; metadata from ASHRAE catalogue / Handbook descriptions only. Citation only.
Citation
ASHRAE TC 9.9 (2024). ASHRAE Datacom Series (TC 9.9) - series overview incl. IT Equipment Power Trends 3rd ed., Best Practices for Datacom Facility Energy Efficiency 2nd ed., Particulate and Gaseous Contamination 2nd ed., Green Tips. ASHRAE. Datacom Series Books 2, 6, 8, 10. https://www.ashrae.org/technical-resources/bookstore/datacom-series
Events on this subject
- ISK-SODEX Istanbul 2027
- SC26 – International Conference for High Performance Computing, Networking, Storage and Analysis
- Data Center World Middle East
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.