Data center solutions powering the digital economy
Danfoss
A Danfoss portfolio brochure (India edition) mapping its products onto data-centre cooling and power subsystems; a component checklist for a cooling plant rather than a design method.
On this page
Overview
The brochure covers air-cooled chillers, precision air units, liquid-cooling connectors and CDU components, pump stations, solid-state transformers, heat-recovery modules and fan walls. Each section lists the relevant components (Turbocor compressors, VFDs, micro-channel and plate heat exchangers, balancing valves, couplings, sensors) with headline performance figures.
On the cooling side: Turbocor oil-free compressors are quoted with up to 38 °C maximum chilled-water output for air-cooled chillers; all-aluminium micro-channel heat exchangers are claimed to give up to 30% better performance with lower refrigerant charge and glycol compatibility for dry/free cooling; gasketed plate heat exchangers reach an approach temperature as low as 1 °C.
On the electrical side, iC7 ULH air-cooled pump drives are quoted at 3-5% THDi or less, with ultra-low supraharmonics and no common-mode voltage. An Advanced Active Filter with SiC switches is quoted at 98.2% efficiency. The solid-state transformer converts MV AC directly to LV DC with a single 11 MW converter.
For liquid cooling, OCP-inspired UQD/UQDB couplings are used in-rack and FD83 couplings out-of-rack on CDU loops. The figures are the manufacturer's own promotional values and their test conditions are not detailed in the brochure.
Key points
- Turbocor oil-free compressors are quoted with up to 38 °C maximum chilled-water output in air-cooled chillers.
- All-aluminium micro-channel heat exchangers: up to 30% better performance, lower refrigerant charge, glycol-compatible.
- iC7 ULH pump drives quoted at 3-5% THDi or less, ultra-low supraharmonics, no common-mode voltage.
- Advanced Active Filter with SiC switches quoted at 98.2% efficiency.
- Gasketed plate heat exchangers reach approach temperatures as low as 1 °C.
- OCP-inspired UQD/UQDB couplings in-rack and FD83 couplings out-of-rack for CDU loops.
- The solid-state transformer converts MV AC to LV DC with a single 11 MW converter.
Using it in design
- In the cooling-plant builder keep a component list per subsystem (chiller, CDU, pump skid, heat recovery) with fields for maximum chilled-water temperature, HX approach temperature and VFD THDi.
- When liquid cooling is selected, require the in-rack and out-of-rack quick-disconnect types to be specified.
- Model low-harmonic drives as reduced harmonic sources in the power-quality calculation.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Check cooling capacity alongside your design
Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.
Request a demo
Who should read it
Mechanical designers and procurement teams scanning the component scope of a data-centre cooling plant.
Related standards
- OCP UQD specification
- AHRI
Publication details
- Authors
- Danfoss
- Publisher
- Danfoss
- Year
- 2026
- Document number
- AM570745408300en-IN0101
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Citation
Danfoss (2026). Data center solutions powering the digital economy. Danfoss. AM570745408300en-IN0101. https://assets.danfoss.com/documents/latest/600967/AM570745408300en-IN0101.pdf