AWS Unveils AI Data Center Designs Supporting 6x Increase in Density (David Chernicoff)
Data Center Frontier · David Chernicoff
A Data Center Frontier article analyses the AI-oriented data centre design changes AWS announced at re:Invent 2024.
On this page
Overview
The article was written by David Chernicoff and published by Data Center Frontier in 2024. It analyses the AI-oriented data centre design changes AWS announced at re:Invent 2024: simplified electrical and mechanical systems, backup power moved closer to racks, a hybrid liquid/air cooling rack design that can be retrofitted, a new power shelf and software-driven server placement to cut stranded power.
It is a news analysis of a vendor announcement; the figures are AWS's claims and are not independently verified. AWS claims about 12% more compute power per site from the new designs. Simplified power conversion is claimed to reduce inefficiency and failure risk by 20%. Bringing backup power closer to the racks cut the number of electrical racks affected by issues by 89%. Fan energy is reduced by using natural pressure differentials to exhaust hot air. The liquid-to-chip rack design, configurable and retrofittable, can cut mechanical energy by up to 46% and supports air- and liquid-cooled gear in one facility.
The new rack power shelf targets a 6x increase in rack power density over two years, then a further 3x. AWS claims higher compute per site, lower energy and better availability. Limit: there is no detailed engineering data or independent measurement, so the claims should be read as indicators of design direction.
Key points
- AWS claims about 12% more compute power per site from the new designs.
- Simplified power conversion is claimed to reduce inefficiency and failure risk by 20%.
- Bringing backup power closer to the racks cut the number of electrical racks affected by issues by 89%.
- Fan energy is reduced by using natural pressure differentials to exhaust hot air.
- Liquid-to-chip rack design can cut mechanical energy by up to 46% and supports air- and liquid-cooled gear in one facility.
- The new rack power shelf targets a 6x increase in rack power density over two years, then a further 3x.
Using it in design
- Support hybrid air/liquid halls and rack-level or near-rack backup power topologies in the design library.
- Track stranded power per rack or row and expose it as a KPI.
- Allow fewer conversion stages in power chain templates.
- Use the vendor claims (12%, 20%, 89%, 46%) as target scenarios, not as verified data.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Designers and technology leaders planning data centre architecture for AI workloads.
Publication details
- Authors
- David Chernicoff
- Publisher
- Data Center Frontier
- Year
- 2024
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Citation
David Chernicoff (2024). AWS Unveils AI Data Center Designs Supporting 6x Increase in Density (David Chernicoff). Data Center Frontier. https://www.datacenterfrontier.com/design/article/55247074/aws-unveils-ai-data-center-designs-supporting-6x-increase-in-density