Socomec MASTERYS BC+ 60 to 80 kVA PEP SOCO-00119-V01.01-EN
Socomec
The product environmental profile (PEP) for Socomec's MASTERYS BC+ 60-80 kVA UPS range; a source record holding one independently worded fact for preliminary sustainability calculations.
On this page
Overview
This record is the source metadata for the 2024 product environmental profile (PEP) of Socomec's MASTERYS BC+ 60-80 kVA UPS range, reference SOCO-00119-V01.01-EN. Its purpose is to provide independently worded facts that can be used in preliminary sustainability calculations. The document is reference-only; its full text is not redistributed. A PEP is a type of environmental declaration reporting a product's environmental impacts over its life cycle.
The record holds a single numerical fact: the battery-free 72 kW MASTERYS BC+ 80 kVA reference UPS has an A1-A3 climate impact of 0.146 kg CO2e per 100 W-year. Multiplied by the declared-unit factor of 10800, this gives 1576.8 kg CO2e per UPS, or 21.9 kg CO2e per rated kW. The value belongs to the manufacturing stage (A1-A3) and appears on pages 2, 6 and 7 of the document.
The limit on its use is explicit: product-specific data must be clearly labelled proxies when applied to generic equipment. The value belongs to a battery-free reference UPS; it should not be taken as directly valid for a different rating, a configuration with batteries or another manufacturer, and should be used only as a proxy for preliminary estimates. This caution keeps preliminary calculations from giving a false impression of precision.
Key points
- Document: Socomec MASTERYS BC+ 60-80 kVA PEP, SOCO-00119-V01.01-EN, 2024.
- Reference product: battery-free 72 kW MASTERYS BC+ 80 kVA UPS.
- A1-A3 climate impact 0.146 kg CO2e per 100 W-year.
- Declared-unit factor 10800.
- Result: 1576.8 kg CO2e per UPS.
- 21.9 kg CO2e per rated kW.
- When applied to generic equipment the value must be clearly labelled a proxy.
Using it in design
- In preliminary sustainability calculations, estimate UPS manufacturing (A1-A3) carbon with the proxy value of 21.9 kg CO2e per rated kW and label it clearly as a proxy.
- For configurations with batteries, add the batteries' impact separately; this value is for the battery-free reference.
- When a specific product is chosen, replace the proxy with the manufacturer's own PEP data.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Sustainability analysts and electrical designers doing preliminary carbon-footprint and lifecycle calculations.
Publication details
- Authors
- Socomec
- Publisher
- Socomec
- Year
- 2024
- Document language
- English
- Source type
- Manufacturer
- Access
- Citation only
- Licence
- Bibliographic reference only — the document is not redistributed here; confirm reuse terms at the original source
Citation
Socomec (2024). Socomec MASTERYS BC+ 60 to 80 kVA PEP SOCO-00119-V01.01-EN. Socomec. https://www.socomec.fr/sites/default/files/2025-09/MASTERYS-BC-60-to-80-KVA_PEP_2025-08-20-15-18-34_SOCO-00119-V0101-EN_English_PLURI_0.pdf
Events on this subject
- Electricity Eurasia 2027
- The smarter E Europe (Intersolar Europe, ees Europe, Power2Drive, EM-Power)
- Data Centre World Paris
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.