WP#75 - Server Energy Efficiency in Data Centers and Offices
The Green Grid · Jay Dietrich, Jeff Doolittle et al.
The Green Grid's 2017 white paper comparing idle-power and SERT-based active-efficiency metrics as regulatory measures of server efficiency.
On this page
Overview
This white paper compares idle-power and SERT-based active-efficiency metrics as regulatory measures of server efficiency, using a deployed-power methodology. It is dated 7 November 2017 and edited by Jay Dietrich (IBM). Related documents include ISO/IEC 21836 (SERT) and Regulation (EU) 2019/424.
The deployed-power method uses SERT data to find the server count and power for a target workload. The paper finds that idle-power limits would exclude high-performance servers and could raise data-centre energy; per the abstract's Figure 12, idle-power regulation could result in over 30% higher data-centre energy. The Green Grid advocates the weighted geomean active-efficiency metric based on SERT.
The information comes only from the public description page of The Green Grid library; the full text requires signing in with a free account and is governed by the Terms of Use. It should be kept in mind that the paper reflects an industry body's position and takes a side in the regulatory debate.
Key points
- Dated 7 November 2017; editor Jay Dietrich (IBM).
- The deployed-power method uses SERT data to find server count and power for a target workload.
- Idle-power regulation could result in over 30% higher data-centre energy (paper Figure 12).
- Idle-power limits would exclude high-performance servers.
- Recommends weighted geomean active efficiency based on SERT.
- Related: ISO/IEC 21836 (SERT) and Regulation (EU) 2019/424.
- Full text requires a free TGG account.
Using it in design
- In the server catalogue, store the SERT active-efficiency score together with idle power.
- Size the IT load from workload and performance, not from idle power alone.
- When comparing server options, base the comparison on deployed power (server count x power) for the same workload.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Compare the cost of design decisions
Evaluate equipment costs, energy expenses and total cost of ownership (TCO) using your inputs and assumptions in SoSo CAD.
Request a demo
Who should read it
Designers selecting servers and sizing IT load, and energy specialists following regulatory developments.
Related standards
- ISO/IEC 21836 (SERT)
- Regulation (EU) 2019/424
Publication details
- Authors
- Jay Dietrich; Jeff Doolittle; Gary Verdun; Shahid Sheikh; David Reiner; Henry Wong
- Publisher
- The Green Grid
- Year
- 2017
- Document number
- WP 75
- Document language
- English
- Source type
- Industry body
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.
Citation
Jay Dietrich; Jeff Doolittle; Gary Verdun; Shahid Sheikh; David Reiner; Henry Wong (2017). WP#75 - Server Energy Efficiency in Data Centers and Offices. The Green Grid. WP 75. https://www.thegreengrid.org/en/resources/library-and-tools/496-WP%2375---Server-Energy-Efficiency-in-Data-Centers-and-Offices
Events on this subject
- iMasons Climate Accord Summit
- ICCI 2027 – Uluslararası Enerji ve Çevre Fuarı ve Konferansı
- The smarter E Europe (Intersolar Europe, ees Europe, Power2Drive, EM-Power)
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.