WP#95 Water Usage Impact (WUI) v1 Metric
The Green Grid · The Green Grid DCRE Standing Work Group
WUI relates consumed water to the water stress of the site's location, so the same litre counts for more in a scarce basin.
On this page
Overview
This 2025 paper (no. 95) releases the Water Usage Impact metric from the DCRE framework as a standalone publication. The idea is simple: WUE only states litres per kWh, but the impact of a litre depends on where it is drawn. WUI relates consumed water to the water-stress level of the location, producing a proxy that reflects that difference. The paper exists to separate cases where WUE reads the same in litres per kWh but the impact differs by basin.
Because it pulls out only the water half of the framework, the paper should be read with DCRE (WP 93), which also includes energy and climate zone, while WUI concentrates on the water-to-stress relationship. A WUI scoring calculator is published in the library alongside it, so the metric is not purely conceptual and has a tool for producing a score per site.
The record does not say which source supplies the stress level, what range the scale has or what the coefficients are, and the full text requires sign-in. This page therefore describes the concept and where it fits, and gives no numbers. The related standard is ISO/IEC 30134-9. Results should not underpin a design decision until the calculator's inputs have been verified.
Key points
- WUI is a proxy for the environmental impact of consumed water relative to local water stress.
- The same litre counts for more in a high-stress basin.
- WUI is a sub-component of the DCRE framework, released here on its own.
- A WUI scoring calculator accompanies it in the library.
- Published 2025 as v1; related standard ISO/IEC 30134-9.
Using it in design
- Put a water-stress rating beside WUE on the site-selection screen.
- Show a warning when evaporative cooling is selected at a high-stress site.
- Do not conflate WUI with DCRE: use WUI when only the water view is needed, DCRE when energy and climate are wanted too.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Check cooling capacity alongside your design
Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.
Request a demo
Who should read it
Designers weighing water risk while choosing a cooling technology, and site-assessment teams.
Related standards
- ISO/IEC 30134-9
Publication details
- Authors
- The Green Grid DCRE Standing Work Group
- Publisher
- The Green Grid
- Year
- 2025
- Document number
- WP 95
- Document language
- English
- Source type
- Industry body
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Citation
The Green Grid DCRE Standing Work Group (2025). WP#95 Water Usage Impact (WUI) v1 Metric. The Green Grid. WP 95. https://www.thegreengrid.org/resources/library-and-tools/wp95-water-usage-impact-wui-metric
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.