Technical guideFree to read2025

National Flood Hazard Layer (NFHL)

Federal Emergency Management Agency (FEMA)

FEMA's NFHL is a geospatial database of current effective US flood hazard data compiled from effective Flood Insurance Rate Maps and Letters of Map Change, covering over 90% of the US population.

On this page

Overview

The National Flood Hazard Layer (NFHL) is a geospatial database of current effective flood hazard data for the United States, supporting the National Flood Insurance Program. It is built from effective flood maps and Letters of Map Change and covers over 90% of the US population.

Access is through the Map Service Center (address search, FIRMettes, shapefiles), the NFHL Viewer, GIS web services and a KMZ for Google Earth. New and revised data are added continuously, and a Flood Map Changes Viewer shows preliminary or pending changes. The page was last updated on 3 April 2025. It is a primary data source for flood screening in US data-centre site selection.

Key points

  1. NFHL is a geospatial database of current effective flood hazard data supporting the National Flood Insurance Program.
  2. It is built from effective flood maps and Letters of Map Change.
  3. It covers over 90% of the US population.
  4. Access is via the Map Service Center, NFHL Viewer, GIS web services and KMZ.
  5. New and revised data are added continuously; the Flood Map Changes Viewer shows pending changes.

Using it in design

  • In US site pre-screening, query the candidate parcel in NFHL to determine its flood zone class.
  • Add the FIRMette or GIS layer from the official service to the site selection file.
  • Check preliminary or pending map changes with the Flood Map Changes Viewer and reflect them in design elevation decisions.
  • Re-evaluate the elevation of critical electrical and mechanical equipment against the flood hazard data.

Who should read it

Engineers, consultants and risk managers selecting data-centre sites and assessing flood risk in the US.

Related standards

  • ASCE 24
  • FEMA 543

Publication details

Authors
Federal Emergency Management Agency (FEMA)
Publisher
Federal Emergency Management Agency (FEMA)
Year
2025
Document language
English
Source type
Government / public
Access
Free to read
Licence
U.S. public domain: U.S. Government work; free to reuse
Original licence note

U.S. federal government data and web content (FEMA). Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Federal Emergency Management Agency (FEMA) (2025). National Flood Hazard Layer (NFHL). Federal Emergency Management Agency (FEMA). https://www.fema.gov/flood-maps/national-flood-hazard-layer

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.