RFC 7432: BGP MPLS-Based Ethernet VPN
IETF / RFC Editor · A. Sajassi (Ed.), R. Aggarwal et al.
A 2015 IETF Standards Track RFC defining EVPN, which distributes MAC addresses in BGP and specifies four route types, single-active and all-active multihoming, MAC mobility and DF election.
On this page
Overview
RFC 7432 is the Standards Track document that defines Ethernet VPN (EVPN) to overcome VPLS limitations in multihoming and redundancy, multicast optimisation, provisioning simplicity, flow-based load balancing and multipathing. Motivation and requirements are given in RFC 7209. EVPN moves MAC address learning from the data plane into the BGP control plane and adds extensions to existing IP/MPLS protocols.
The EVPN NLRI is carried in BGP Multiprotocol Extensions (AFI 25, SAFI 70) and four route types are defined: Ethernet Auto-Discovery, MAC/IP Advertisement, Inclusive Multicast Ethernet Tag and Ethernet Segment. An Ethernet segment is identified by a 10-octet ESI. A multihomed segment runs in single-active or all-active redundancy mode; in all-active mode, aliasing and backup path mechanisms provide load balancing and fast convergence.
Multihoming functions include segment auto-discovery, fast convergence, split horizon (using the ESI label) and designated forwarder (DF) election, where the default timer is 3 seconds. Multi-destination traffic is carried with ingress replication or P2MP LSPs, and unknown unicast packets are handled similarly.
The MAC mobility section governs the movement of a MAC address between PEs and the detection of continuous moves (MAC duplication): by default, N = 5 moves within M = 180 seconds is taken as a loop. Static (sticky) MAC addresses can be exempted from this check. The document assumes an MPLS transport layer; data centre encapsulations such as VXLAN are addressed in separate documents.
Key points
- EVPN moves MAC learning into the BGP control plane; the NLRI uses AFI 25 (L2VPN) and SAFI 70.
- Four route types: Ethernet A-D, MAC/IP Advertisement, Inclusive Multicast Ethernet Tag, Ethernet Segment.
- An Ethernet segment is identified by a 10-octet ESI; ESI types run from 0 to 5 (for example, type 1 is LACP-based).
- Redundancy modes are single-active and all-active; in all-active mode aliasing spreads load across several PEs.
- The default DF election timer is 3 seconds.
- The default MAC mobility check treats 5 moves in 180 seconds as a loop indication.
- Ingress replication or P2MP LSPs carry multicast and unknown unicast.
- Split horizon uses the ESI label to stop broadcast traffic returning to the same segment.
- It is a Standards Track document (February 2015) answering the RFC 7209 requirements.
Using it in design
- Where servers attach to two leaf switches, plan the ESI and DF election strategy up front for all-active multihoming.
- Review MAC mobility thresholds (180 seconds, 5 moves) against virtual machine migration intensity and define critical MACs as static where needed.
- Include BGP session count and route table size by route type in the capacity calculation.
- Choose between ingress replication and P2MP LSPs for multicast according to infrastructure capability.
Who should read it
Data centre and service provider network architects, engineers designing EVPN-based overlays and teams planning multihomed redundancy.
Document contents
- Introduction
- Terminology
- EVPN Overview
- Ethernet Segment
- BGP EVPN NLRI
- Multihoming Functions
- Handling of Multi-destination Traffic
- Forwarding Unicast Packets and Load Balancing
- MAC Mobility
- Multicast and Broadcast
- Convergence
- Frame Ordering
- Security Considerations
Related standards
- RFC 8365
- RFC 7348
Publication details
- Authors
- A. Sajassi (Ed.); R. Aggarwal; N. Bitar; A. Isaac; J. Uttaro; J. Drake; W. Henderickx
- Publisher
- IETF / RFC Editor
- Year
- 2015
- Document number
- RFC 7432
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
IETF Trust copyright under the Trust Legal Provisions; link and cite.
Citation
A. Sajassi (Ed.); R. Aggarwal; N. Bitar; A. Isaac; J. Uttaro; J. Drake; W. Henderickx (2015). RFC 7432: BGP MPLS-Based Ethernet VPN. IETF / RFC Editor. RFC 7432. https://doi.org/10.17487/RFC7432
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
