RFC 9135: Integrated Routing and Bridging in Ethernet VPN (EVPN)
IETF / RFC Editor · A. Sajassi, S. Salam et al.
A 2021 IETF Standards Track RFC specifying how EVPN performs inter-subnet routing (IRB) at the leaf: symmetric and asymmetric IRB, the distributed anycast gateway and the EVPN Router's MAC community.
On this page
Overview
EVPN provides multihoming-capable intra-subnet connectivity among virtual or physical tenant systems over MPLS/IP networks. Where inter-subnet connectivity must be dynamic and efficient, an IRB solution is needed, and RFC 9135 defines EVPN-based IRB for it. The PE model: for a tenant needing IRB, a PE has an IP-VRF and one or more MAC-VRFs; each bridge table (a VLAN, typically one subnet) connects to the IP-VRF through an L3 interface called the IRB interface.
Two IRB types are defined. In symmetric IRB both ingress and egress PEs perform lookups on MAC and IP: the ingress PE does a MAC lookup followed by an IP lookup, and the egress PE does an IP lookup followed by a MAC lookup. Traffic is routed between IP-VRFs, so each PE holds ARP only for local hosts. In asymmetric IRB the ingress PE both routes and bridges while the egress PE only bridges, so all PEs must hold remote ARP entries and all subnets. The tables are a logical view and real implementations may differ for performance.
An anycast default gateway with the same IP and MAC on every PE is recommended. In the control plane, MAC/IP routes signal symmetric versus asymmetric mode through Label2 and route targets, and symmetric routes carry the EVPN Router's MAC extended community. Subnet (RT-5) routes let remote PEs forward to subnets whose hosts are not yet learned. The document also covers host mobility (gratuitous ARP, data sent without an ARP request, silent host) and operational models for symmetric inter-subnet forwarding on NVEs.
These routing models are used in most EVPN-VXLAN data-centre fabrics. The operational section notes that a PE advertises different routes depending on whether it is configured for symmetric or asymmetric IRB, a difference to account for in mixed-mode deployments.
Key points
- A 2021 Standards Track RFC defining inter-subnet routing (IRB) in EVPN.
- PE model: one IP-VRF per tenant, one or more MAC-VRFs; each bridge table connects to the IP-VRF through an IRB interface.
- Symmetric IRB: ingress and egress PEs route between IP-VRFs; each PE holds ARP only for local hosts.
- Asymmetric IRB: the ingress PE routes and bridges, the egress PE only bridges; all PEs must hold remote ARP entries and all subnets.
- An anycast default gateway with the same IP and MAC on every PE is recommended.
- MAC/IP routes indicate symmetric or asymmetric mode via Label2 and route targets; symmetric routes carry the EVPN Router's MAC extended community.
- Subnet (RT-5) routes let PEs forward to subnets whose hosts are not yet learned.
- Host mobility is covered for gratuitous ARP, data without an ARP request, and silent hosts.
Using it in design
- Choose symmetric or asymmetric IRB by subnet scale: in asymmetric mode count the fact that every leaf holds all subnets and remote ARP entries in capacity planning.
- Plan the same IP and MAC for the distributed anycast gateway on every leaf and record it in the addressing scheme.
- Verify in commissioning the route differences advertised by PEs in mixed symmetric and asymmetric mode.
- Test host mobility (gratuitous ARP and silent host) with workload-migration scenarios.
- Add EVPN Router's MAC extended community and RT-5 support to the device compliance list.
Who should read it
Network architects designing EVPN-VXLAN fabrics and engineers choosing the leaf-level routing model.
Document contents
- Introduction and Terminology
- EVPN PE Model for IRB Operation
- Symmetric and Asymmetric IRB: IRB interface and its MAC and IP addresses, operational considerations
- Symmetric IRB Procedures: control plane (advertising and receiving PE), subnet route advertisement, data plane (ingress and egress PE)
- Asymmetric IRB Procedures
- Mobility Procedure: gratuitous ARP, data without ARP request, silent host
- BGP Encoding: EVPN Router's MAC Extended Community
- Operational Models for Symmetric Inter-Subnet Forwarding
- Security and IANA Considerations
Related standards
- RFC 7432
- RFC 8365
Publication details
- Authors
- A. Sajassi; S. Salam; S. Thoria; J. Drake; J. Rabadan
- Publisher
- IETF / RFC Editor
- Year
- 2021
- Document number
- RFC 9135
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
IETF Trust copyright under the Trust Legal Provisions; link and cite.
Citation
A. Sajassi; S. Salam; S. Thoria; J. Drake; J. Rabadan (2021). RFC 9135: Integrated Routing and Bridging in Ethernet VPN (EVPN). IETF / RFC Editor. RFC 9135. https://doi.org/10.17487/RFC9135
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.